11 - MAINTENANCE
11.1 CHECKLIST FOR RECOMMENDED REGULAR CHECKS
Notes/interventions suggested to the owner
*Refer to the local provisions for implementation; in an extremely brief and purely indicative manner, the regulation specifies the following.
Companies and technicians carrying out installation, maintenance/repair interventions, checks for losses and recovery operations must be CERTIFIED in
accordance with the local regulations.
The check for losses must be carried out an an annual basis.
Disconnect the power supply before each operation.
Checking content
Checking frequency
Action
1
Air filter (inlet/outlet)
Every month
Clean the filter
2
Anode
Every 6 - 12 months
Replace it if it has been used out
3
Inner storage tank
Every half year
Clean the
storage tank
4
Electric heater
Every half year
Clean the resistance
5
Saftey valve
Every year
Turn the knob
If water doesn't flow freely when operating the handle, replace safety valve with a new one
6
Water filter
Every year
Clean the filter
7
Expansion vessel
Every year
Check charge
8
Checking for leaks*
Every year
Check
Check the connection between power supply plug and socket and ground wiring regularly;
The missing or lacking maintenance of the magnesium anode, can lead to the corrosion of the storage tank with a subsequent loss of
water and the warranty coverage and the manufacturer responsibility fall.
It is recommended to clean the inner storage storage tank and e-heater to keep an efficient performance.
It is recommended to set a lower temperature to decrease the heat release, prevent scale and save energy if the outlet water volume
is sufficient.
Clean the air filter every month in case of any inefficiency on the heating performance.
Checks effected on…………………...………….......by…………………………...…...……………………….of the company……………………………………..