Sinclair ASH-18AIN PT User Manual Download Page 19

Installation Services

Precautions on Installation 

4.  Ensure safe grounding and the grounding wire shall be connected with the special grounding 

equipment of the building and must be installed by professional technicians. In the fixed line there 

must be an electrical leakage protection switch and an air switch with sufficient capacity. The air 

switch shall also have the magnetic tripping and thermal tripping functions to achieve protection of 

both short-circuit and overload. 

5.  The minimum clearance between air conditioner and flammable surface is 1.5m. 

Grounding Requirement 

1.  As air-conditioning unit is of Class I electrical appliance, reliable grounding measures must be taken 

for it. 

2.  The double color (yellow and green) cable inside the air conditioner is for grounding and shall not be 

used for other purposes nor can it be cut. Do not tighten with tapping screw; otherwise electric 
shock will be caused. 

3.  The ground resistance shall be in conformity with the requirements of state standard GB17790. 
4.  The user power supply shall have reliable grounding terminal. It is prohibited to connect the 

grounding wire to the following items: 

 
 
 
 

 NOTE:

 1.    All the electrical work must be done by qualified personnel according to relative wiring regulation and 
        this manual.
 2.    The power supply is type Y connection. If the supply cord is damaged, it must be replaced by the 
        manufacturer or its service agent or a similarly qualified person in order to avoid a hazard.
 3.    The rated voltage and the exclusive circuit must be used.
 4.     Leakage circuit-breaker and air switch of correct capacity must be installed. The air switch of 32A
         should be used in these models.
 5.    The plug must be accessible after the appliances have been positioned. 
 6.    A air switch having a contact separation of at least 3mm in all poles should be fixed in fixed wiring.
 7.    Fuse size:25A/250VAC
 
 
 
 
 
 
 
 
  

  Water Supply Pipe 

 Gas Pipe 

 Sewage Pipe  

  Other positions that are considered to be unreliable by professionals.

 
 
 

 
 
 

 
 
 

 
 

 
 

 
 
 
 
 

 
 

 
 
 

 

-16-

Summary of Contents for ASH-18AIN PT

Page 1: ...USER S MANUAL ASH 18AIN PT ASH 24AIN PT ...

Page 2: ......

Page 3: ...tions on Installation 15 Installation Dimension Drawing 17 Install Indoor Unit 18 Install Outdoor Unit 2 0 Test Run and Checks after Installation 21 This mark indicates the matter that shall be prohibited This mark indicates the matter that must be followed Welcome to select SINCLAIR air conditioner For correct use of this air conditioner please keep this Manual properly for future reference Remot...

Page 4: ...the air conditioner out of use Never damage the cable or use unapproved cable Otherwise it might cause electric shock or fire Otherwise accumulation of dust might cause heating or fire Otherwise it might result in cable overheating and cause fire Please turn off the power before cleaning the air conditioner cut off the power Otherwise it might cause electric shock or injury Rated voltage of this a...

Page 5: ...ective to avoid When the air conditioner is running do not keep the door and window of the room long open Never block the air inlet or outlet of indoor and outdoor unit Spraying chemicals and coal gas tank must be placed 1m away from the indoor and outdoor unit Otherwise the effect of air conditioner will be decreased As this will decrease the effect of air conditioner or cause shutdown or even fi...

Page 6: ...er or any stick into the indoor or outdoor outlet Otherwise injuries may be caused Never blow the air directly at pets or plants as this may cause harm to them Never spray water onto the unit or wash the air conditioner with water Otherwise fault or electric shock may be caused Never let the air conditioner blow against the heater Otherwise the burning will be incomplete and result in carbon monox...

Page 7: ...y change in performance parameters the data provided on nameplate shall prevail Working temperature range Indoor side DB WB C Outdoor side DB WB C Maximum cooling 32 23 43 26 T1 Maximum cooling 21 15 18 Maximum heating 20 24 Maximum heating 20 14 15 Cooling Heating rated current A Cooling Heating rated power W Cooling Heating power input W Recycling air Volume m 3 h Refrigerant and weight kg Water...

Page 8: ...ger of outdoor unit may frosted after the air conditioner has run for a period of time This will decrease the heating effect In this case auto defrost function will be activated and the heating mode will temporarily stopped for 8 10 minutes Both the indoor fan and outdoor fan will be stopped during auto defrost During defrost the indicator on indoor unit will blink and steam might flow from the in...

Page 9: ...Panel 2 Guide louver 3 Receiving window 5 Wall Pipe 6 Wrapping Tape 7 Drainage hose 8 Connection pipe Air inlet Air Outlet 6 Air inlet Air Outlet 7 6 and connection wire Wireless remote control Heat This indicator is black for single Cooling cooling unit Set Temp 8 4 LED Board ...

Page 10: ...EP function when repressing once more to stop the function When the unit start up under the AUTO COOL FAN HEATmode press this button could select Auto fan Low fan Middle fan High fan at DRY mode the fan speed is Low fan speed The FAN SPEED can be memorized under various modes At unit turned on press this button the AUTO COOL DRY FAN or HEAT mode could be selected When pressing this button once the...

Page 11: ...same with T ON Every press of this button the unit will be turned on when repressed the unit will be turned off When pressing this button once enter into T ON setting the icon of T ON flash every press of TIME the time of T ON will be increased 1min When continuously press 1sec above the tens place on minute will be increased 1 every press of TIME will be decreased 1 minute when continuously press...

Page 12: ...urn on the unit At unit off press the manual switch the unit will enter into AUTO running state automatically The microcomputer will accord to the indoor temperature to select COOL HEAT FAN in order to achieve the insulators Turn off the unit When unit is running press the manual switch STOP button the unit will stop running Manual switch Plasma Technology PLASMA TEC Plasma Air Purification Techno...

Page 13: ... of the panel into supporting groove Cover up the panel along arrow direction and clamp it See Fig 4 a b Fig 4 a b 1 Lift up the front panel along arrow direction Pull the groove on two ends of the front panel with force to remove the front panel Note Clean the air filter more frequently if the air conditioner is used under dusty environment To avoid injury do not touch the fins of indoor unit wit...

Page 14: ...is rusted paint on the rusty position to prevent expansion Check the air inlet outlet on indoor and outdoor units for any blocking Check the earthing cable for reliability Check the battery of remote controller for replacement Check the mounting frame of outdoor unit for damage If damaged please contact SINCLAIR Authorized Service Center Install the air filter Mount the air filter along arrow dire...

Page 15: ... started or the compressor is started or stopped during running or the air conditioner is stopped sometimes you may hear hua hua or di du di du noise This is the flowing sound of refrigerant other than fault This might occur when indoor temperature and humidity are high This is because the indoor air is quickly cooled down After a period of time the fog will disappear with the decrease of indoor t...

Page 16: ... range or blocked by any obstacles Check the battery in remote controller for power level If low power replace the battery If the remote controller is damaged Water leaks from indoor unit Air humidity is high Condensing water overflows Joint of indoor unit drain pipe is loose Water leaks from outdoor unit Under cooling mode water might condense on pipe or pipe joint due to cooling Defrosted water ...

Page 17: ...re Moisture exists on outlet grill If the air conditioning is long running under high humidity moisture might condense on the grill and drop down In case of following events please contact SINCLAIR Authorized Service Center Air conditioner gives out shrill noise during running Air conditioner gives out bad smell during running Water leaks indoors Air break switch or leakage protection switch trips...

Page 18: ...he unit in a place where the children can not reach 4 Choose a place where the weight of indoor unit can be withstood and operating noise and vibration are not increased 5 Ensure sufficient clearance and space for service and maintenance Ensure the indoor unit is at least 2 4m from the floor 6 Choose a position at least 1 meter from any TV sound system or other household electric appliances 7 Choo...

Page 19: ...se electric shock will be caused 3 The ground resistance shall be in conformity with the requirements of state standard GB17790 4 The user power supply shall have reliable grounding terminal It is prohibited to connect the grounding wire to the following items NOTE 1 All the electrical work must be done by qualified personnel according to relative wiring regulation and this manual 2 The power supp...

Page 20: ...Dimension Drawing 17 From the ceiling Over 15cm From the Wall Over 15cm Over 15cm From the Wall Over 300cm Over 240cm Discharge Side Above the floor From the Obstacles Over 30cm From the Wall Over 50cm From the Wall Discharge Side 572 342 Over 30cm Over 200cm Over 50cm ...

Page 21: ...flexible drainage pipe passing through the indoor unit must be wrapped by thermal insulation material Connection of Indoor and Outdoor Cables 1 Pull open the front panel from the above page 10 Fig5 a 2 Unscrew the screw fixing the covering plate of terminal board Fig 7 3 Pass the power cable through a separate cable duct on the back of indoor unit and pull it out from the front 5 Place the section...

Page 22: ...g pipe from bottom case Use adhesive tape to bondage the fitting pipe electrical cable and drain hose properly and then pass them through the fitting pipe hole See Fig 10 3 Hung the claws at the rear side of the indoor unit to the hook on the wall mounting frame Move the unit left and right to see if it is steady See Fig 11 4 The installation height of the indoor unit must be at least 2 4m Install...

Page 23: ...ondensate Water of Outdoor Unit Cooling Only Unit Does Has Such Valve When the air conditioning unit is in the heating mode the condensate water generated at the outdoor unit and the water generated by defrosting shall be drained through the drainage pipe to proper place Installation methods As shown in Figure insert the drainage joint of the outdoor unit into the Φ25 hole on the base plate Connec...

Page 24: ...ormity with requirements The unit may bread down or the components may be burned out Are there any obstacles near the air inlet and outlet of the indoor and outdoor units The unit may bread down or the components may be burned out Have the length of refrigerating pipe and refrigerant charge amount been recorded It is not easy to decide the charge amount of refrigerant Test Run 1 Preparation of Tes...

Page 25: ...ANT CHARGE Pursuant to Regulation EC 842 2006 on certain fluorinated greenhouse gases in case of extra refrigerant charge it is compulsory to Fill in the label accompanying the unit inserting the factory quantity of refrigerant charge see the technical label the extra refrigerant charge and the total charge Apply the label next to the technical label applied on the unit For the split type air cond...

Reviews: