![Sinclair ASH-18AIM2 PT Service Manual Download Page 12](http://html1.mh-extra.com/html/sinclair/ash-18aim2-pt/ash-18aim2-pt_service-manual_1280156012.webp)
8
Technical Information
Service Manual
Indoor unit
Outdoor unit
COOLING
HEATING
4-Way valve
Discharge
Suction
Heat
exchanger
(evaporator)
Heat
exchanger
(condenser)
Valve
Valve
Liquid pipe
side
Gas pipe
side
Strainer
Capillary
Strainer
Accumlator
Compressor
4. Refrigerant System Diagram
Connection pipe specification:
Liquid pipe:1/4" (6mm)
Gas pipe:1/2" (12mm)(ASH-18AIM2 PT)
Gas pipe:5/8" (16mm)(ASH-24AIM2 PT)