25
6.Reassemble the clampand wiring cover.
7.Recover the surface panel.
Install the indoor unit
1.When routing the piping and wiring from the left or right side of the in-
door unit , cut off the tailings from the pipe holder in necessary (shown in
Fig.5).
Through the hole when routing the wiring only.
Cut off the tailings l when routing both the wiring and piping.
2.Wrap the piping and wiring and pull them through the cut - off - tailings
hole (shown in Fig.6).
3.Hang the 2 mounting slots of the indoor unit on the upper tabs of the real
panel and check if it is firm enough.
4.The height of the installed location should be 2.3m or more from the floor.
INST
ALL THE INDOOR UNIT
Install the indoor unit
Fig.4
NOTE:
All the electrical work must be done by qualified personnel according to the local rules and this manual.
The rated voltage and the exclusive circuit must be used.
Leakage circuit - breaker must be installed.
Please use specified fuse.
If the power supply cord of the unit is damaged, it must be replaced by the manufacturer or its service agent or
a similarly qualified person in order to advoid a hazard.
The diameter of power cord should be large enough.Use the exclusive wire to replace the damaged wire.
Wiring work should conform to relative standard.
66122452.p65
03-7-15, 17:26
25