![Sinclair ASH-09AP Service Manual Download Page 17](http://html1.mh-extra.com/html/sinclair/ash-09ap/ash-09ap_service-manual_1280149017.webp)
Operating Procedures / Photos
Open
the three screw covers at the front case,
unscrew the three screws, pull open the clasp
at
the front case, and remove the front case.
4 .
Disassemble Front Case
Screw Screw cover Front case
Clasp
Hold the electric box cover to press it inward so
that the clasps on top loose and remove the
electric box cover.
5 .
Disassemble Electric Box Cover
Electric Box Cover
Clasp
6.Disassemble Electric Box
Grounding wire
Screw
Remove the grounding wire of the evaporator.
Remove the tube sensor. Disconnect the
connecting cable of the indoor motor, use
screwdriver to remove the screw fixing the electric
box, and pull open the clasp at the side of the
board of the indicator light. Take out the electric
box.