Press +and - buttons simultaneously to lock or unlock the keyboard. If the remote controller 
is locked, the icon
flicker for three times. If the keyboard is unlocked, the mark will disappear. 

1. Press swing up and down button continuously more than 2s,the main unit will swing back 

and forth form up to down, and then loosen the button, the unit will stop swinging and present 
position of guide louver will be kept immediately.

2. Under swing up and down mode, when the status is switched from off to     , if press this

button again 2s later,     status will switch to off status directly; if press this button again 
within 2s,the change of swing status will also depend on the circulation sequence stated above. 

About switch between Fahrenheit and Centigrade

Under status of unit off, press +and - buttons simultaneously to switch

℃ and 

It indicates: after starting this function by remote controller and the unit has been under 
defrost status, If turn off the unit by remote controller, the unit will not stop defrosting until 
it is finished; if change setting mode by remote controller, the function ,which is set last 
time, won't be carried out until defrosting finished.
Operation of this function on or off: If remote controller is under off status, press mode button 
and blow     

button simultaneously in order to enter or cancel this new function. If the unit is under 

defrost mode, dual eight position on remote controller will display H1.If switch to heat mode,
the position will display H1, which flickers for 5s, in which case, press  +/- button, H1 will 
disappear and  setting temp. be displayed. 
After remote controller is powered  on, the new defrost function will be defaulted to be closed. 

About swing up and down

About lock

About new function of defrosting 

        will be displayed on it, in which case, press any button, the mark will

Operation of wireless remote control

1.

   

.

.

3.


Slightly to press the place with   

 

  , along the arrowhead direction to push the back cover of wireless 

 

remote  

control. (As show in figure)

Take out the old batteries. (As show in figure)
 Insert two new AAA1.5V dry batteries, and pay attention to the polarity. 

 (As show in figure)
 Attach the back cover of wireless remote control. (As show in figure)

When changing the batteries, do not use the old or different batteries,  

If the wireless remote control will not be used for a long time, please 

otherwise, it can cause the malfunction of the wireless remote control.

take them out, and don't let the leakage liquid damage the wireless 

remote control.

The operation should be in its receiving range.
It should be placed at where is 1m away from the TV set or stereo sound sets.
If the wireless remote control can

 

not operate normally, please take them out, 

 after 30s later and reinsert, if they cannot normally run, please change them.

Sketch map for 

changing batteries

NOTE:

Changing batteries and notices

Summary of Contents for ASH-09AK PT

Page 1: ...USER S MANUAL KING SERIE ASH 09AK PT ASH 13AK ASH 18AK ASH 24AK PT ...

Page 2: ...control Clean and care Troubleshooting Installation service Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Test operation and check after installation This symbol stands for the items should be forbidden This symbol stands for the items should be followed Emergency operation The figures in this manual may be different with the material objects plea...

Page 3: ...Thank you for choosing SINCLAIR air conditioner For correct operation please carefully for consultation read this owner s manual carefully before operating the unit and keeps it ...

Page 4: ...peration of wireless remote control Clean and care Troubleshooting Installation service Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Test operation and check after installation This symbol stands for the items should be forbidden This symbol stands for the items should be followed Emergency operation The figures in this manual may be different wi...

Page 5: ...e the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged and may cause electric shock or fire Please read the following carefully before operating Notic...

Page 6: ... them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately At operating the louvers of air conditioner could be adjusted by pressing the SWING button on wireless remote control to change the airflow direction Swing louver Guide louver Please don...

Page 7: ...this time the auto defrosting function will act the heat running will stop for 8 10mins During the auto defrosting the fan motors of indoor unit and outdoor unit will stop During the defrosting the indoor indicator flashes the outdoor unit may emit vapor This is due to the defrosting it isn t malfunction After defrosting finished the heating will recover automatically Anti freezing function In HEA...

Page 8: ...ames and functions of each part Indoor unit Air in Air out Manual switch Front panel Filter Guide louver Receiving window Bind tape Connection wire Drainage pipe Remote control Outdoor unit Air in Air out ...

Page 9: ... this function is not available Press this button Auto Low Middle High speed can be circularly selected After FAN button FAN powered on Auto fan speed is default Under Blow mode Low fan speed only can be set up Low fan High fan Press this button the clock can be set up signal blink and display Within 5 CLOCK button CLOCK seconds the value can be adjusted by pressing or button if continuously press...

Page 10: ...will be automatically cancelled if changing the mode or fan speed Press this button at unit On or Off status Light On and Light Off can be set up LIGHT button LIGHT After powered on Light On is defaulted Presetting temperature can be increased Press this button the temperature can be button set up continuously press this button and hold for two seconds the relative contents can quickly change unti...

Page 11: ...Hold pressing or button 2 seconds later it quickly change the way of change is During the initial 2 5 seconds ten numbers change in the one place of minute then the one place is constant ten numbers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer button the timer setting succeeds The Timer On has been set up repress the timer button the Timer On wi...

Page 12: ...y 3 Pressing or button to set the desired temperature It is unnecessary to set the temp at AUTO mode 4 Pressing FAN button set fan speed can select AUTO FAN LOW MID and HIGH 5 Pressing button to select the swing 1 Press SLEEP button to set sleep 2 Press TIMER ON and TIMER OFF button can set the scheduled timer on 3 Press LIGHT button to control the on and off of the displaying part of the unit Thi...

Page 13: ...new function If the unit is under defrost mode dual eight position on remote controller will display H1 If switch to heat mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to be closed About swing up and down About lock About new function...

Page 14: ...erature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code swich can be operated as follow At operation When the unit is stopped running adjust the code switch to AUTO the unit will enter into AUTO RUN mode The microcomputer will accord to the room tempera...

Page 15: ...rrows to lift the front panel up meanwhile to hold both slots of the front panel and take it out forcibly and then can take it off Washing Clean with a soft brush water and neutral detergent and then to dry it Note Never use the water above 45 to wash the panel or it could cause deformation or discolouration Install front panel Place two supporters of the front panel into the slots along the direc...

Page 16: ...r unit to prevent it from spreading a b Clean and care Take down the air filter Cleaning Reinsert the filters Reinsert the filters along with the arrow head then cover the surface panel and clasp it To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 When the filters are very dirty such as o...

Page 17: ...n air conditioner is running under cooling mode You may hear a slight crack when the air conditioner is started or stopped The air conditioner itself has no bad smell If any It is the bad smell accumulated from environment Solution Clean the air filter If still any problem the air conditioner shall be cleaned Please contact Authorized Service Center When the air conditioner is started or the compr...

Page 18: ...t of the plug and reinsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed When the unit is running in COOL mode the pipe and...

Page 19: ...he plug If unit is running under the high humidity for a long time the moisture will be condensed on the air outlet grill and drip off In HEAT mode when the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 3min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger...

Page 20: ... The height of the installed location should be 230 cm or more from the floor 6 Select a place about 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be easily taken out 8 Make sure that the indoor unit installation should accord with installation dimension diagram requirements Outdoor Unit Installation Position Selection 1 Select a location from wh...

Page 21: ...ke sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 1 5m It should be reliably earthed and it should be connected to the special earth device the installation work should be operated...

Page 22: ...ling Above Above Above Above Space to the wall Space to the wall Space to the wall Above Above A b o v e m c 0 3 50cm 0 2 0 15cm 15cm 300 cm 2 15 cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e m c 0 2 m c 0 Above 30cm Above cm cm 230 ...

Page 23: ...lood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation materials Wrenched Bent Flooded Indoor Outdoor Wall pipe Seal pad Fig 1 Rear piping hole Rear piping hole Left Right Mark on the middle of it Gradienter Space to the wall 150mm above Space to the wall 150mm above Wall Wall Connect indoor and outdoor electric wires 1 Open the front panel upwardly 2...

Page 24: ... when routing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show in Fig 3 Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 4 Install the c...

Page 25: ... then connect the corresponding connector 5 1 0 10 pa 76cmHg 5 Air purging and leakage test Liquid pipe Gas pipe Valve cap Vacuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle handle of Lo manifold valve 4 Open the vacuum pump ...

Page 26: ...lation Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Outdoor drain elbow Install outdoor unit Fig 6 Use soap water or leak hunting meter to check whether the joints is leak Indoor unit check point Indoor unit check point Leak hunting ...

Page 27: ...ure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooling heating capacity Has the length of connection pipes and refrigerant capacity been recorded The refrigerant capacity is not accurate Test Operation 1 Before test operation 1 Do not switch on power...

Page 28: ...ANT CHARGE Pursuant to Regulation EC 842 2006 on certain fluorinated greenhouse gases in case of extra refrigerant charge it is compulsory to Fill in the label accompanying the unit inserting the factory quantity of refrigerant charge see the technical label the extra refrigerant charge and the total charge Apply the label next to the technical label applied on the unit For the split type air cond...