SECTION THREE
INSTALLATION
After choosing a suitable location (see previous section) install the unit as follows:
Note
: This unit is suitable for wall or eave mounting. Be sure to rotate the sensor head so that
the Time and Lux adjusters are on the underside of the sensor when the unit is mounted.
The unit is suitable for connection to a 220~240 V ac 50Hz electricity supply. It is suggested that
2-core cable of 1mm
2
gauge is used. An isolating switch should be installed to switch the power
to the unit ON & OFF. This allows the sensor to be easily switched off when not required or for
maintenance purposes.
The unit can be wall or ceiling mounted (diagram E). Mark the position of the fitting holes.
Drill the holes. Insert the raw plugs into the holes.
*** IMPORTANT ***
Switch off the electricity at the fuse box by removing the relevant fuse or switching off
the circuit breaker before proceeding with the installation.
CONNECTION
Wiring connections should be made directly into the unit’s wiring.
1. Remove the backplate by unscrewing the two retaining screws.
2. Pass the cable through the entry grommet and secure under the cable clamp.
3. Fix mounting plate to wall/eave (Diagram F)
4. Connect the cable to the terminals :
NEUTRAL = Blue
LIVE = Brown
5. Re-fit the junction box to the mounting plate, ensuring the foam gasket is correctly in place
(Diagram G).
When installing the PAR 38 lamps, ensure the rubber gasket is securely fitted to cover the metal
rim of the lamp and the lampholder (Diagram H).
6. Take care not to overtighten the screws to prevent damage to the mounting plate. If using a
power screwdriver, use the lowest torque setting.