background image

STOP

STOP

STOP

2/4

Checking the motor’s rotation direction

3

Parameters

4

3.1-

 Powering on the product: the display indicates the value 

3.2-

 Check the motor’s rotation direction using the 

 et 

 keys

- If the operation is reversed, power off the product, and revert the motor’s wiring (terminals 7 and 9).

Refer to the motor's installation manual to set the end stop system.

3.3-

  Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the parameter 

 with a value slightly above (+4 sec.) the time 

observed ( 

 : Motor operating time from 

 to 

, 2 sec. increments)

- Press and hold the key 

 to open the door.

- Press and hold the key 

 to close the door.

-  Use the 

 and 

 keys to browse the menu and display the parameter 

required. One second after releasing the key, the screen indicates the parameter 
value to change. (display blinks).

-  Use the 

 and 

 keys to change the value of the parameter. The last value is recorded automatically (the 

display is fixed when pressing the keys).

-  To return to the menu, press the 

 or 

 to return to value 

 (or any other value indicating the product’s operation: see § 5) or after a one-minute wai-

ting time.

4.1- Configuring the operating mode: Parameter

 

 (factory setting = 

 )

-  Certain operating modes impose connecting safety accessories (NF EN 12453). Non compliance with these rules can lead to a facility hazardous for its users.

RSA Hz PRO has six operating modes:

1s.

  The default modes correspond to the main part of installations and uses of roller garage doors.Nevertheless, the RSA Hz PRO control box can be completely and 
easily programmed in order to obtain a personalized working according to the accessories connected and the specific working mode desired by the user.

 - 

 : Automatic mode:

 Pressing the remote control opens and 

closes automatically after timeout 

. During closing, pressing the 

remote control again or the detection of an obstacle reopens the door.

 : Closing time of the door (

 to 

, 1sec. increments)

 Mandatory installation of safety accessories.

 - 

 : Forced mode with the 

 and 

 keys on the key-

board (default mode):

 This mode is used to control the door using the 

 and 

 keys on the RSA Hz PRO box in the endstop adjustment 

phase.
- Press and hold 

 

to open the door.

- Press and hold 

 

to close the door.

 In this mode, the safety devices are not activated

 - 

 : Sequential mode:

 Cyclic operation (up / stop / down / 

stop...). Pressing during opening or closing stops without reversion.

 - 

 : 3-button mode:

 This mode is used to set separate controls for opening, 

closing, and stopping the door.

 - 

 : Semi-automatic mode:

 Pressing the control triggers opening or closing. 

Pressing again during opening has no effect. Pressing during closing reopens the door.

 - 

 : Sequential mode + Timeout:

 Similar to the sequential mode, but with 

automatic closing aftert timeout 

.

 : Closing time of the door (

 to 

, 1sec. increments)

Summary of Contents for RSA Hz PRO

Page 1: ...u Hz transmitters Different safety and signaling systems can be connected to the RSA Hz PRO safety edge photocells flashlights area lighting This product complies with recognized technical standard and safety regulation When carrying out wiring and installation work always refer to current standards This contributes to implementing installations complying with the standard safety in using motorise...

Page 2: ...se rules can lead to a facility hazardous for its users RSA Hz PRO has six operating modes 1s The default modes correspond to the main part of installations and uses of roller garage doors Nevertheless the RSA Hz PRO control box can be completely and easily programmed in order to obtain a personalized working according to the accessories connected and the specific working mode desired by the user ...

Page 3: ...nected to safety input 2 enabled when closing the door ADMAP safety active upon closing forbids starting at opening Contact for connecting an emergency stop device No accessories connected to safety input 3 default mode Accessory connected to safety input 3 enabled when opening the door Accessory connected to safety input 3 enabled when closing the door ADMAP safety active upon closing forbids sta...

Page 4: ... s operation Contact to drive a zone lighting default mode automatic switch off after timeout T3 4 8 Contact to drive an Orange flashlight with notice before starting and during the door s operation Contact to drive an electromagnetic latch Contact to drive an open door indicator Contact of the stable mono relay type to drive an automation system Contact of the unstable relay type to drive an auto...