Checking the motor’s rotation direction
3
Parameters
4
3.1-
Powering on the product: the display indicates the value
3.2-
Check the motor’s rotation direction using the
et
keys
- If the operation is reversed, power off the product, and revert the motor’s wiring (terminals 7 and 9).
-
Refer to the motor's installation manual to set the end stop system.
3.3-
Measure the motor operating time using permanent running (e.g. 20sec. for rising), then set the parameter
with a value slightly above (+4 sec.) the time
observed (
: Motor operating time from
to
, 2 sec. increments)
- Press and hold the key
to open the door.
- Press and hold the key
to close the door.
- Use the
and
keys to browse the menu and display the parameter
required. One second after releasing the key, the screen indicates the parameter
value to change. (display blinks).
- Use the
and
keys to change the value of the parameter. The last value is recorded automatically (the
display is fixed when pressing the keys).
- To return to the menu, press the
or
to return to value
(or any other value indicating the product’s operation: see § 5) or after a one-minute wai-
ting time.
4.1- Configuring the operating mode: Parameter
(factory setting =
)
- Certain operating modes impose connecting safety accessories (NF EN 12453). Non compliance with these rules can lead to a facility hazardous for its users.
RSA Hz PRO has six operating modes:
1s.
The default modes correspond to the main part of installations and uses of roller garage doors.Nevertheless, the RSA Hz PRO control box can be completely and
easily programmed in order to obtain a personalized working according to the accessories connected and the specific working mode desired by the user.
-
: Automatic mode:
Pressing the remote control opens and
closes automatically after timeout
. During closing, pressing the
remote control again or the detection of an obstacle reopens the door.
-
: Closing time of the door (
to
, 1sec. increments)
Mandatory installation of safety accessories.
-
: Forced mode with the
and
keys on the key-
board (default mode):
This mode is used to control the door using the
and
keys on the RSA Hz PRO box in the endstop adjustment
phase.
- Press and hold
to open the door.
- Press and hold
to close the door.
In this mode, the safety devices are not activated
-
: Sequential mode:
Cyclic operation (up / stop / down /
stop...). Pressing during opening or closing stops without reversion.
-
: 3-button mode:
This mode is used to set separate controls for opening,
closing, and stopping the door.
-
: Semi-automatic mode:
Pressing the control triggers opening or closing.
Pressing again during opening has no effect. Pressing during closing reopens the door.
-
: Sequential mode + Timeout:
Similar to the sequential mode, but with
automatic closing aftert timeout
.
-
: Closing time of the door (
to
, 1sec. increments)