14 |
Wiring |
10kW and 25kW Installation Manual
9.
In the lower half of the housing, secure the cable under the cable clamp. The cable should
have enough slack to not interfere with opening or closing of the case.
10.
Fit the cable gland assembly. Use silicon sealant around the cable entry point.
11.
Use silicon sealant around the mounting bolts
12.
Close the pedestal and fi rmly secure it with the screws.
Earth the 10 kW scanner
The earth point must be connected to the vessel’s ground system.
1.
Connect one end of the copper Earth strop (2) to the bolt (1) on the pedestal.
2.
Connect the other end of the Earth strop to the mounting location using the Earth bolt (3).
3.
Apply silicon sealant around both of the bolts.
Note:
If the radar mounting location is not made of a electrically conductive material, fi t a
longer earth strap that allows direct connection to the vessel’s ground.