Junction D and G - multicore to 2 wire junction
Ú
Note:
The terminal block supplied with the junction box shall not be used.
Dimensions:
20 mm
30 mm
60 mm
X mm
Cut the unused wires in the multicore cable in different lengths to avoid short-circuiting
wires.
Step by step instructions:
•
Slide the provided braided shield sleeve over one of
the cables
•
Remove the outer insulation of the 2-wire cable
•
Push back the cable´s braided shield
•
Remove insulation from the conductors
•
Remove the outer insulation of the multicore cable
•
Remove the aluminum foil that surrounds the wires
•
Separate the wires to be used from the other wires
•
Remove insulation from the conductors to be used
•
Connect the conductors to be used with crimp
joiners using a professional crimp tool
•
Seal the joints with self-vulcanizing tape
•
Separate the shield wires from the other wires in the
multicore cable
•
Cut the unused wires in the multicore cable in
different lengths to avoid short-circuiting wires
•
Apply self-vulcanizing tape over the cut cables and
the joint
•
Pull the braided shield and shield wires over the
joint
•
Pull the provided braided shield sleeve over the
joint
•
Seal the joint with self-vulcanizing tape
Wiring
| S3009 Echo Sounder User Manual
31