
The Alerts dialog
The Alerts dialog is activated from the Alert settings or from the main menu.
The Alerts dialog includes a list of active alerts together with a historic listing of the last alert
state changes. Entries are added to the history whenever an alert is raised, acknowledged,
rectified or cleared.
All alerts in the Alerts dialog include a time stamp.
Alphabetic alert list
Alert type abbreviations:
•
C: Caution
•
A: Alarm
Alert text
Description
Type
BAM heartbeat lost
No HBT message is received. Only relevant if one or
more NMEA 0183 ports are configured as BAM interface.
C
Depth missing
No depth data from selected sensor
C
Low voltage
Supply voltage <10 V (12V-15%)
C
No time source
No time data from NMEA 2000 or NMEA 0183 position
sensor. Only relevant if the time setting is Auto.
C
Shallow water
Depth shallower then set limit
A
The alert system
| S3009 Echo Sounder User Manual
23