Simrad S-band HSC SRT Installation Manual Addendum Download Page 3

| 3

S-band HSC SRT Adapter Box | 

Installation Guide Addendum

The following block diagram displays the S-band in configuration HSC:

AB + CD= Standard Up Mast

Cable

15 m: 000-10332-001
30 m: 000-10333-001
60 m: 000-10334-001

A

B

C

D

Cable composition

NUMBER

CABLE TYPE

COLOR

1

RG59 coaxial

Black

2

RX174 coaxial

Black

3

1.5 mm

2

 single core

Red

4

1.5 mm

2

 single core

Black

5

2.5 mm

2

 single core

Red

6

2.5 mm

2

 single core

Black

7

2.5 mm

2

 single core

Green/Yellow

8

2 x 0.35 mm

2

 shielded twisted pair

Blue

9

Black

10

2 x 0.35 mm

2

 shielded twisted pair

White

11

Black

12

2 x 0.35 mm

2

 shielded twisted pair

Green

13

Black

14

2 x 0.35 mm

2

 shielded twisted pair

Red

15

Black

16

0.35 mm

2

 single core

White

17

0.35 mm

single core

Blue

18

0.35 mm

single core

Red

Summary of Contents for S-band HSC SRT

Page 1: ...ENGLISH S bandHSCSRTAdapterBox Installation Guide Addendum navico commercial com ...

Page 2: ... ft antenna ANT12LP S 001 000 13193 001 S band SRT 30 KW up mast HSC UPMAST S 002 000 13194 001 S band HSC SRT adapter box unit SRTAB 001 Alternative standard installation cables Part number Description 000 10332 001 15 m pre wired SRT up mast cable kit 000 10333 001 30 m pre wired SRT up mast cable kit 000 10334 001 60 m pre wired SRT up mast cable kit SRT adapter box dimensions WARNING HIGH VOLT...

Page 3: ...coaxial Black 2 RX174 coaxial Black 3 1 5 mm2 single core Red 4 1 5 mm2 single core Black 5 2 5 mm2 single core Red 6 2 5 mm2 single core Black 7 2 5 mm2 single core Green Yellow 8 2 x 0 35 mm2 shielded twisted pair Blue 9 Black 10 2 x 0 35 mm2 shielded twisted pair White 11 Black 12 2 x 0 35 mm2 shielded twisted pair Green 13 Black 14 2 x 0 35 mm2 shielded twisted pair Red 15 Black 16 0 35 mm2 si...

Page 4: ...llation instructions is to identify the wires inside the cable and connect to the new power supply Tools Needed Cutter Plastic cable ties 5 5 mm hexagonal 5 mm Allen key 10 mm flat spanner Phillips screwdriver Scissors and tongs AMP mod2 Wiring procedure For installation you need 50 cm of free cable C cable to SRT up mast S band pedestal Cable from core unit B ...

Page 5: ...s in Fig 12 14 and 15 5 Connect the black cable on the negative screws of the Power supply as in Fig 17 6 Connect the red wires on 2T1 of relay K1 as in Fig 18 7 If an external safety control switch is needed open the link as in Fig 19 and connect the external switch Note Fig 8 shows four black cables Make sure to identify the RX174 coaxial the RG59 coaxial the 1 5 mm wire and the 2 5 mm wire Fig ...

Page 6: ...s Fig 8 2 5 mm black wires Fig 9 Isolate the active 48 V wire coming from the core unit Fig 10 Open the cable gland 5 5 mm Fig 11 Use the 10 mm flat spanner Fig 12 Insert cable C Fig 13 Close with cable B and tighten Fig 14 Insert all cables into the slot Fig 15 Close and tighten ...

Page 7: ...P S Fig 18 Red on antenna safety relay Fig 19 Link for external switch Testing and commissioning 1 Connect the 220 V power supply to the SRT adapter box 2 Switch on the unit s main switch 3 Connect a test lead to relay pin 2T1 GND must be present 48 VDC 15 4 Close the box and test the S band antenna at HSC speed ...

Page 8: ... 988 11129 001 www navico commercial com ...