Installation instructions for SRT adapter box 

S-band HSC 12 feet array

Introduction

This is a dedicated instruction to carry out an Argus S-band HSC installation using a standard 
cable and an additional S-band HSC SRT adapter box.
To obtain the S-band in HSC, install one module SRT adapter box, part number 000-13194-
001, unit type SRTAB-001. Inside there is a multi-voltage power supply with 1000 W 48 VDC.

Items covered by this guide

Part number

Description

Unit type

000-11250-001

12 ft antenna

ANT12LP/S-001

000-13193-001

S-band SRT 30 KW up-mast HSC

UPMAST/S-002

000-13194-001

S-band HSC SRT adapter box unit

SRTAB-001

Alternative standard installation cables:

Part number

Description

000-10332-001

15 m pre-wired SRT up-mast cable kit

000-10333-001

30 m pre-wired SRT up-mast cable kit

000-10334-001

60 m pre-wired SRT up-mast cable kit

SRT adapter box dimensions 

WARNING

HIGH VOLTAGE IS PRESENT INSIDE

COVER MUST BE OPEN BY

SKILLED PERSONNEL ONLY

370

400

116

300

(min. distance to the floor)

28

360

320

Installation

The SRT module must be installed in between the Core unit and the S-band SRT 30 KW 
up-mast HSC, part number 000-13193-001, unit type UPMAST/S-002.
It must be installed in a protected area close to the Core unit.

Summary of Contents for S-band HSC SRT

Page 1: ...ENGLISH S bandHSCSRTAdapterBox Installation Guide Addendum navico commercial com ...

Page 2: ... ft antenna ANT12LP S 001 000 13193 001 S band SRT 30 KW up mast HSC UPMAST S 002 000 13194 001 S band HSC SRT adapter box unit SRTAB 001 Alternative standard installation cables Part number Description 000 10332 001 15 m pre wired SRT up mast cable kit 000 10333 001 30 m pre wired SRT up mast cable kit 000 10334 001 60 m pre wired SRT up mast cable kit SRT adapter box dimensions WARNING HIGH VOLT...

Page 3: ...coaxial Black 2 RX174 coaxial Black 3 1 5 mm2 single core Red 4 1 5 mm2 single core Black 5 2 5 mm2 single core Red 6 2 5 mm2 single core Black 7 2 5 mm2 single core Green Yellow 8 2 x 0 35 mm2 shielded twisted pair Blue 9 Black 10 2 x 0 35 mm2 shielded twisted pair White 11 Black 12 2 x 0 35 mm2 shielded twisted pair Green 13 Black 14 2 x 0 35 mm2 shielded twisted pair Red 15 Black 16 0 35 mm2 si...

Page 4: ...llation instructions is to identify the wires inside the cable and connect to the new power supply Tools Needed Cutter Plastic cable ties 5 5 mm hexagonal 5 mm Allen key 10 mm flat spanner Phillips screwdriver Scissors and tongs AMP mod2 Wiring procedure For installation you need 50 cm of free cable C cable to SRT up mast S band pedestal Cable from core unit B ...

Page 5: ...s in Fig 12 14 and 15 5 Connect the black cable on the negative screws of the Power supply as in Fig 17 6 Connect the red wires on 2T1 of relay K1 as in Fig 18 7 If an external safety control switch is needed open the link as in Fig 19 and connect the external switch Note Fig 8 shows four black cables Make sure to identify the RX174 coaxial the RG59 coaxial the 1 5 mm wire and the 2 5 mm wire Fig ...

Page 6: ...s Fig 8 2 5 mm black wires Fig 9 Isolate the active 48 V wire coming from the core unit Fig 10 Open the cable gland 5 5 mm Fig 11 Use the 10 mm flat spanner Fig 12 Insert cable C Fig 13 Close with cable B and tighten Fig 14 Insert all cables into the slot Fig 15 Close and tighten ...

Page 7: ...P S Fig 18 Red on antenna safety relay Fig 19 Link for external switch Testing and commissioning 1 Connect the 220 V power supply to the SRT adapter box 2 Switch on the unit s main switch 3 Connect a test lead to relay pin 2T1 GND must be present 48 VDC 15 4 Close the box and test the S band antenna at HSC speed ...

Page 8: ... 988 11129 001 www navico commercial com ...

Reviews: