1
Alert management system
2
Blue wire – alarm output (N/C isolated contact)
3
Yellow wire – alarm output negative return
4
Red wire - positive DC supply (24 VDC system)
5
Black wire - negative DC supply (24 VDC system)
6
Fuse - see table at end of section
7
DC supply
Connection of Ethernet cable to control unit
The Ethernet cable is pre-terminated and is simply plugged directly to the R3016 Control
unit's NETWORK connector. Under no circumstance should this cable be plugged into a
network hub or any other Ethernet device.
Ú
Note:
Direct connection must be made between the transceiver and controller. Failure
to do so would make the system non-compliant.
Sensor connection
Any sensor connected to the R3016 12U/6X system should meet IMO performance standards
and be certified. Failure to do so would make the rest of the system non-compliant.
The R3016 control unit supports up to 4 inputs and 2 outputs for sensors. Expansion beyond
the supplied 4 inputs and 2 outputs can be achieved by the addition of an SI80 through
connection to the control unit’s NMEA 2000 port.
All inputs and outputs can be configured to match the speed of the connected sensors.
Sensor connection overview diagram
The diagrams below show the configuration of a system with 5 inputs using the SI80 for
expansion, as well as a system only using the 4 on-board inputs.