PI Configurator
237
850-165186 / Rev.B
How to configure a Twin Spread system
This procedure describes hot to set up a Twin Spread system
using one Twin Spread sensor and two Remote sensors.
Setting up the Twin Spread sensor
1
Connect the Twin Spread sensor to the PI Configurator.
2
Press
Establish communication with Sensor
.
- Observe that the current sensor configuration
parameters are displayed in the message field. The
information includes sensor type, channel number, and
the sensor’s software version.
3
If required, select new communication channels in the
spin boxes next to the
Communication channel
labels.
- Two communication channels are required because the
Twin Spread system measures two different distances.
The channels you select here MUST match the
channels you select on the PI44.
4
If required, select a different update rate in the spin box
next to the
Data update rate
label.
5
Use the spin box next to the
Remote
label to choose the
set of Remote sensor you wish to use.
- You can either use Remote set
1 and 3
or
2 and 4
.
- The selection you make here MUST match the two
Remote sensors you wish to use.
6
Press the
Configure sensor
button to upload the new
parameters.
7
Press
Terminate communication
, and disconnect the
sensor.
Setting up the first Remote sensor
1
Connect the first Remote sensor to the PI Configurator.
2
Press
Establish communication with Sensor
.
- Observe that the current sensor configuration
parameters are displayed in the message field.
3
Use the spin box next to the
Number
label to define the
sensor’s number in the Twin Spread system.
- The number you choose MUST match one of the
numbers chosen in step 5 in the Twin Spread sensor
setup.
4
Press the
Configure sensor
button to upload the new
parameters.
5
Press
Terminate communication
, and disconnect the
sensor.