Simrad PI54
106
850-165186 / Rev.B
You can select the communication channels between the
PI
Spread
sensors and the vessel to suit your preferences.
Special configuration of PI Twin Spread
The
PI Twin Spread
sensor is always used with two
PI Remote
sensors, and these must be configured as a group in order to
make the transverse communication links work properly. In
order to allow for a dual Spread application, you can use two
predefined configurations:
PI Twin Spread 1
and/or
PI Twin
Spread 2
.
The
Remote
sensors are available pre-programmed for these
two pairs, and the sensors are identified as
Remote 1
,
Remote
2
,
Remote 3
and
Remote 2
. The two first (1 and 2) are the same
sensors as for the standard PI Spread application.
The two groups must be configured as follows:
Configuration
Spread sensor
Remote sensors
PI Twin Spread 1
PI Twin Spread (*) Remote 1
Remote 3
PI Twin Spread 2
PI Twin Spread (*) Remote 2
Remote 4
(*) = The same
PI Twin Spread
sensor is used for both configurations.
By default, it is programmed for
PI Twin Spread 1
. If you wish to use it
for
PI Twin Spread 2
, you must re--configure it using the
PI Configura-
tor
application.
You can select the communication channels between the
PI
Twin Spread
sensors and the vessel to suit your preferences.