Recommended parameter settings

RECOMMENDED PARAMETER SETTINGS

When the PI HBU (Hydrophone Booster Unit) is put to use, the
recommended parameter settings are changed.

Simrad PI32

The following

Receiver setup

parameters are recommended when

the PI HBU (Hydrophone Booster Unit) is put to use.

Interference filter

: OFF

– Switch ON if interference is still a problem. As an

alternative, you may keep the filter OFF, and increase the

Detection threshold (DT)

setting in steps of 2 dB until the

interference disappears.

Interference filter level

: 9

– If you switch the interference filter ON, you may change

the level to 8.

AGC

: OFF

Manual gain

: 20 dB

Max shooting speed

: 1 kn

– In order to maintain best possible reception during the

shooting you may increase this setting to 5 kn.

Detection threshold (DT)

: 8 dB

The other settings are not important.

Figure 3

PI30 Receiver Setup, example

Simrad PI44 and PI54

When the PI HBU (Hydrophone Booster Unit) is put to use, the
recommended parameter settings are changed.

326153/A

7

Summary of Contents for PI HBU

Page 1: ...Instruction manual Simrad PI HBU Hydrophone Booster Unit T E C H N O L O G Y F O R S U S T A I N A B L E F I S H E R I E S www simrad com...

Page 2: ......

Page 3: ...Simrad PI HBU Hydrophone Booster Unit Instruction Manual This document allows you to install and put to use the PI HBU Hydrophone Booster Unit 326153 A 08 January 2008...

Page 4: ...manual applies must only be used for the purpose for which it was designed Improper use or maintenance may cause damage to the equipment and or injury to personnel The user must be familiar with the c...

Page 5: ...Instruction Manual Table of contents ABOUT 5 PI HBU HYDROPHONE BOOSTER UNIT 6 RECOMMENDED PARAMETER SETTINGS 7 Simrad PI32 7 Simrad PI44 and PI54 7 INSTALLATION 9 326153 A 3...

Page 6: ...Simrad PI HBU 4 326153 A...

Page 7: ...ut ABOUT This document allows you to install and put to use the PI HBU Hydrophone Booster Unit Figure 1 PI HBU Hydrophone Booster Unit Figure 2 Commercial power supply provided with the PI HBU 326153...

Page 8: ...oftware release 1 08 provided an increased range capability By using the PI HBU Hydrophone Booster Unit as well the systems will offer additional range and they will be more tolerant for noise On PI32...

Page 9: ...er OFF and increase the Detection threshold DT setting in steps of 2 dB until the interference disappears Interference filter level 9 If you switch the interference filter ON you may change the level...

Page 10: ...switch the interference filter ON you may change the level to 7 Sensor filter LIGHT Catch Bottom sensor filter LIGHT AGC OFF Manual gain 20 dB Multipath filter OFF If you use the PI Geometry sensor th...

Page 11: ...e between the units 4 Mount the PI HBU unit 5 Power down your PI system 6 Disconnect the hydrophone connector on the rear side of the PI operator unit and connect it to the PI HBU unit A Figure 5 PI H...

Page 12: ...g s b e rg M a rit im e A S S t ra n d p rom e n a d e n 5 0 P O Box 1 1 1 N 3 1 9 1 H ort e n N orwa y S im r a d Te le p h on e 4 7 3 3 0 3 4 0 0 0 Te le fa x 4 7 3 3 0 4 2 9 8 7 con t a ct s im ra...

Reviews: