Installation
INSTALLATION
Observe the procedure to install the PI HBU (Hydrophone
Booster Unit).
1
Unpack the PI HBU (Hydrophone Booster Unit) unit.
2
Check that the package contains the unit and a power supply.
3
Find a suitable location for the PI HBU unit.
The unit must be placed close to the PI operator unit, and
within reach of a power outlet (115–230 Vac). Observe the
length of the hydrophone cable, which limits the distance
between the units.
4
Mount the PI HBU unit.
5
Power down your PI system.
6
Disconnect the hydrophone connector on the rear side of the
PI operator unit, and connect it to the PI HBU unit (A).
Figure 5
PI HBU (Hydrophone Booster Unit) connections
A
Hydrophone socket
B
Cable to hydrophone socket on PI operator unit
C
+24 Vdc power socket (use power supply provided
with the PI HBU)
7
Connect the cable from the PI HBU unit (B) to the
hydrophone socket on the rear side of the PI operator unit.
8
Connect the power supply to AC mains, and connect the
power cable to the socket (C) on the PI HBU unit.
9
Power up your PI system.