Simpson PelletVent Pro Installation Instructions Manual Download Page 10

10

Figure 10

Figure 11

3.

  If the flue exits on back of stove and an 

interior installation is desired (Figure 10):

A.  Place the appliance according to the 

manufacturer’s instructions.

B.  Connect the Tee Adapter or combine Tee 

with Cleanout and Pipe Adapter then seal and 

secure the Pipe Adapter to the back of the 

stove. 

C.  Continue to assemble Pipe Sections as 

described in Step 2.

4.

  

If the flue exit is on the back of stove, and 

an exterior vertical installation or partial vertical 

installation is desired (Figure 11):

A.  Place the appliance according to 

manufacturer’s instructions. 

B.

  Cut and frame a square opening in the 

wall as specified in 

Table 1. PelletVent Pro 

now offers the standard Wall Thimble or 

Wall Thimble Air Intake Kit for through the 

wall installations. The Air Intake Kit allows 

combustion air to be drawn through the framed 

Thimble opening, eliminating the need to 

cut another opening in wall. The small flex 

provided with this kit allows connection to 

the Pellet Stove combustion air inlet. Loosely 

assemble both halves of the Wall Thimble onto 

Pipe Section. Connect the flexible hose with 

clamp to the exterior half of the Wall Thimble. 

Guide the flex through the opening in black 

interior half of Wall Thimble, gently pull the 

flex towards appliance 

(Figure 12), and if 

necessary trim excess flex to required length 

with snips. Secure flex to combustion air inlet 

PELLET VENT

PRO PIPE

NorthlineExpress.com

http://www.northlineexpress.com

Toll-Free 1-866-667-8454

Summary of Contents for PelletVent Pro

Page 1: ...t Pro Complete Venting Solutions for the Hearth Industry Installation Instructions Biofuel Venting System For Pellet and Corn Stoves NorthlineExpress com http www northlineexpress com Toll Free 1 866...

Page 2: ...his booklet also contains instructions for installing a venting system within an existing masonry chimney and for installations passing through a cathedral ceiling Dear Customer Installer or End User...

Page 3: ...ractices 5 Tools Needed Permits General Installation Instructions 6 Installation into Masonry Fireplaces 14 Installation Through Side of Masonry Chimney 17 Installation in a Cathedral Ceiling 18 Clean...

Page 4: ...ion products are a minimum of 1 from the vent pipe 2 For horizontal terminations make sure NFPA 211 rules are followed for minimum distance from windows and openings 3 Do not mix and match with other...

Page 5: ...appliance If the exhaust cools to a certain point moisture in the exhaust condenses in the vent which can lead to accelerated vent corrosion Keep the vent for corn burning appliances short wherever p...

Page 6: ...building department or fire officials regarding any needed permits restrictions and installation inspection requirements in your area GENERAL INSTALLATION INSTRUCTIONS PelletVent Pro is listed with a...

Page 7: ...ct Pipe Adapter or Increaser Adapter to stove Due to the variety of different stove collars the Pipe Adapter will need high temperature non hardening sealant in order to achieve a leak free connection...

Page 8: ...8 Figure 6 Figure 7 Figure 4 Figure 5 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 9: ...ng Adjust the height of the Attic Insulation Shield by sliding the top cylindrical shield over the one from the base Insure that the top of the Shield is above the level of building insulation Secure...

Page 10: ...n Table 1 PelletVent Pro now offers the standard Wall Thimble or Wall Thimble Air Intake Kit for through the wall installations The Air Intake Kit allows combustion air to be drawn through the framed...

Page 11: ...e black interior half of the Wall Thimble to the interior wall and the unpainted exterior half are to be secured to the exterior wall on both styles of thimbles Figure 13 The Wall Thimbles adjust to f...

Page 12: ...ll with non hardening waterproof sealant As an option you may also seal the gap between the pipe and Wall Thimble with sealant 5 If the flue exit is on back of the stove and a horizontal through the w...

Page 13: ...or ceiling supported Figure 17 A Remove any existing connector pipe adapter or connector going into the ceiling support box B Visually inspect with a flashlight the condition of the interior of the ch...

Page 14: ...ly read the pellet stove or insert installation instructions 3 Measure and record the dimensions as shown in Figure 18 4 Use dimension A to determine total pipe requirements Add 12 additional inches t...

Page 15: ...in Figure 20 may be made It may be necessary to contact the manufacturer of the unit to determine exactly what may or may not be done to make the correct connection Some typical arrangements are shown...

Page 16: ...Figure 23 Figure 25 Figure 24 16 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 17: ...pletes the masonry installation INSTALLATION THROUGH SIDE OF MASONRY CHIMNEY 1 Set the appliance in its final location and mark the center of the hole where the pipe is to penetrate the masonry chimne...

Page 18: ...2 Position the appliance at its proper location on the floor Pay close attention to the manufacturer s installation instructions regarding the clearance to combustibles etc Position appliance so Supp...

Page 19: ...Figure 29 Figure 30 Figure 31 Figure 28 19 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 20: ...east 12 inches above the roof before attaching Termination Cap Figure 32 10 After all PelletVent Pro Pipe Sections and components are assembled and connected down to the appliance seal and secure the...

Page 21: ...season 4 Do not use chemical cleaners They can damage the vent pipe 5 To increase the life PelletVent Pro coat all exterior metal parts with high temperature rustproof paint This is highly recommended...

Page 22: ...22 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 23: ...23 NorthlineExpress com http www northlineexpress com Toll Free 1 866 667 8454...

Page 24: ...lacement of chimney pipe lengths at 50 of the retail list price in effect at the time of replacement removal and installation costs and 50 of the retail list price paid by Purchaser For 5 years from t...

Reviews: