4.8
Control Switches
Removal and Refitting
I.
Remove the screws holding the top cover of the handle controls.
II.
The coupling plate and contact blocks can be removed from the switch by turning the
release plate.
III.
The individual contact blocks can also be removed if necessary, by unclipping from the
coupling plate.
IV.
The top portion of the switch can be removed by unscrewing the nut under the control
panel.
V.
When refitting, note that the small locating lug on the Raise/Lower switch goes in the cut-
out in the cover.
4.9
12v DC Electric Motor
The motor used on a battery-powered Multi-Tip is an 800 watt, series-wound 12v DC motor. It has
4 brushes which wear down over time; as they are difficult and time-consuming to replace, it is
usually better to fit a complete new motor.
Positive supply to the motor comes through the relay mounted on the side of the motor (see
section 4.6); negative is permanently connected to the motor terminal.
Removal and Refitting
I.
Remove the entire power pack as described in section 5.2.
II.
Undo the 2 cap screws holding the motor to the power pack and lift it away.
III.
The power pack must be held vertical when refitting the motor; ensure the coupling
engages correctly with the pump shaft.
Control
Switches
•
Safety Button
•
Raise/Lower
Buttons
•
Key Switch