D. Location
When choosing a location for your fi replace ensure that
the general rules are followed:
•
For best results, install out of direct sunlight.
•
Power supply service must be installed within
proximity of appliance prior to fi nishing to avoid
reconstruction.
•
See Figure 3.1 for appliance dimensions and to
determine location of appliance installation.
E. Clearance to Combustibles
Minimum Clearance to Combustible Construction
Sides.......................0 in.
Floor................13 3/4 in.
Top..........................0 in.
Back........................0 in.
Front.....................36 in.
See Figure 3.2.
WARNING! Risk of Fire! Keep electrical cords, drapery,
furnishings or other combustibles at least 3 ft. (0.9 m)
from the front of the appliance, and away from the sides
or rear.
F. Electrical Supply Circuit Requirements
Plan the location of the appliance so that it will have
adequate electric power. A 15 AMP, 120V/60hz. circuit
is required. Additional appliances on the same circuit as
this appliance may exceed the current rating of that cir-
cuit. A dedicated circuit is not required, but is preferred
to prevent circuit breaker trips or fuse failure.
Note:
Access to electrical outlet must be maintained.
Figure 3.2 Clearance to Combustibles
ELECTRICAL
OUTLET
LOCATION
Figure 3.3 Electrical Outlet Locaton
FLOOR
WALL
CEILING
350 mm
13-3/4 in.
min