MOUNTING OF COOKER HOOD
Unpack the appliance from packaging.
Drill holes for fasteners according the drawing 3.
Tap the fasteners to drilled holes.
Fix the appliance with provided screws throu
holes “G”
IMPORTANT
The horizontal location of cooker hood should
be observed.
THE EXHAUSTION VERSION
At use of exhaustion version (see fig. 4) the
exhalations are led into the exhaustion opening
with the exhaustion hose, which is connected to
the cooker hood with a flange. The exhaustion
hose and the fastening clips should be bought
additionally.
The exhaustion is provided through the upper
outlet of the cooker hood, on which the
exhaustion hose should be connected and the
other end of hose should be connected into the
exhaustion opening. The diameter of exhaustion
hose should be the same as the diameter of
connecting flange
– e.g. Ø 150mm, or Ø 120mm
with a reduction piece (if you use connection hose
Ø 120mm, you will decrease exhaust capacity
and increase noise level).
MOUNTING OF EXHAUSTION VERSION
AND OF DECORATION CHIMNEY
Fasten with help of a hose clip on the hinged on
cooker hood the one end of exhaustion hose,
fasten the other end into the exhaustion opening.
Both parts (the upper C and lower B) of
decoration chimney, shifted one to the other,
place on the hinged on cooker hood.
Shift the upper part C into the required height,
mark the upper location and mark the fastening
openings of console (K).
Remove the decoration chimney and bore the
marked openings for the dowels.
Screw on the console (K) together with cover of
decoration chimney (M).
Fasten once more the both parts of decoration
chimney, shift out its upper part and fasten to the
console with two screws.
IMPORTANT
Remove protection foil from decoration chimney
not untill last assembly of decoration chimney!
IMPORTANT!
The carbon filter should not be installed in the
cooker hood at exhaustion version.
RECIRCULATION VERSION
A carbon filter and recirculation set should be
bought for the cooker hood in recirculation
version (fig. 9). The exhalations are exhausted
through the carbon filter.(fig. 1 (E)) The circulation
air with removed smell is led with exhausted hose
through air spreader to the ventilation openings in
upper part of decorative chimney to the room.
This version is used in cases, when there is no
waste air stack at disposal.
It is necessary to count with a longer reaction time
at recirculation in automatic regime.
CAUTION!
The carbon filter should be installed in the
cooker hood at recirculation.
SETTING UP OF CAPACITY LEVEL FOR
THE COOKER HOOD
The cooker hood can work in two regimes:
Manual
Automatic
SETTING UP OF COOKER HOOD
CAPACITY LEVEL IN MANUAL MODE
Power level 1, 2, 3 is set by turning the control
knob.
If the control knob is set on 1L, 2L, 3L ventilation
and light is powered together.
SETTING UP OF COOKER HOOD
CAPACITY LEVEL IN AUTOMATIC MODE
The automatic regime can be switched on with
setting of switch button to position „A“ or „AL“. The
cooker hood is running on the capacity level 1 during
60 seconds, the sensor is heated up during this
period. The sensor is ready for operation after
heating up. The sensor thereafter measures
continuously the pollution level of air and according
to the measured value regulates the capacity levels
between 0 and 3.
TURNING ON THE LIGHTS
Light is ON when the control knob is in position “L”.
TURNING OFF THE HOOD
The hood is OFF when the control knob is in position
“0”.
THE COOKER HOOD IS EQUIPPED WITH
THE SAFETY SWITCHING OFF FUNCTION
When the switch button is in a position different to
„A“ or „AL“ and this setting will be not changed
during a period of one week, then the electronic
control of hood will be switched off automatically.
The
cooker
hood
is
then
in
a
condition
corresponding to switch button position 0.
REMARK
The cooker hood electronics regulates the capacity
levels corresponding to gas and vapor concentration
level measured with the sensor. This regulation can
differ from
expectations derived from visual
monitoring of vapor occurrence
.
At recirculation mode the air in the room is not