EN 

                                                                                                                2

 

MOUNTING OF COOKER HOOD 

 

  Unpack the appliance from packaging. 

  Drill holes for fasteners according the drawing 3. 

  Tap the fasteners to drilled holes. 

  Fix  the  appliance  with  provided  screws  throu 

holes “G” 

 

IMPORTANT  

 

The  horizontal  location  of cooker  hood  should 
be observed.

 

 

THE EXHAUSTION VERSION   

 

  At  use  of  exhaustion  version  (see  fig.  4)  the 

exhalations  are  led  into  the  exhaustion  opening 
with  the  exhaustion  hose,  which  is  connected  to 
the  cooker  hood  with  a  flange.  The  exhaustion 
hose  and  the  fastening  clips  should  be  bought 
additionally. 

  The  exhaustion  is  provided  through  the  upper 

outlet  of  the  cooker  hood,  on  which  the 
exhaustion  hose  should  be  connected  and  the 
other  end  of  hose  should  be  connected  into  the 
exhaustion  opening.  The  diameter  of  exhaustion 
hose  should  be  the  same  as  the  diameter  of 
connecting flange 

– e.g.  Ø 150mm, or Ø 120mm 

with a reduction piece (if you use connection hose 
Ø  120mm,  you  will  decrease  exhaust  capacity 
and increase noise level). 

 

MOUNTING OF EXHAUSTION VERSION 
AND OF DECORATION CHIMNEY 

 

  Fasten  with  help  of  a  hose  clip  on  the  hinged  on 

cooker  hood  the  one  end  of  exhaustion  hose, 
fasten the other end into the exhaustion opening. 

  Both  parts  (the  upper  C  and  lower  B)  of 

decoration  chimney,  shifted  one  to  the  other, 
place on the hinged on cooker hood.  

  Shift  the  upper  part  C  into  the  required  height, 

mark  the  upper  location  and  mark  the  fastening 
openings of console (K). 

  Remove  the  decoration  chimney  and  bore  the 

marked openings for the dowels.  

  Screw  on  the  console  (K)  together  with  cover  of 

decoration chimney (M). 

  Fasten  once  more  the  both  parts  of  decoration 

chimney, shift out its upper part and fasten to the 
console with two screws. 

 

IMPORTANT  

Remove protection foil from decoration chimney 
not untill last assembly of decoration chimney! 

 

IMPORTANT! 

 

The  carbon  filter  should  not  be  installed  in  the 
cooker hood at exhaustion version. 

 

RECIRCULATION VERSION 

 

  A  carbon  filter  and  recirculation  set  should  be 

bought  for  the  cooker  hood  in  recirculation 
version  (fig.  9).  The  exhalations  are  exhausted 
through the carbon filter.(fig. 1 (E)) The circulation 

air with removed smell is led with exhausted hose 
through air spreader to the ventilation openings in 
upper part of decorative chimney to the room. 

  This  version  is  used  in  cases,  when  there  is  no 

waste air stack at disposal.  

  It is necessary to count with a longer reaction time 

at recirculation in automatic regime. 

 

CAUTION! 

 

The  carbon  filter  should  be  installed  in  the 
cooker hood at recirculation.  

 

SETTING UP OF CAPACITY LEVEL FOR 
THE COOKER HOOD 

 

The cooker hood can work in two regimes: 

  Manual  

  Automatic 

 

SETTING UP OF COOKER HOOD 
CAPACITY LEVEL IN MANUAL MODE  

  Power  level  1,  2,  3  is  set  by  turning  the  control 

knob. 

  If the control knob is set on 1L, 2L, 3L ventilation 

and light is powered together. 

 

SETTING UP OF COOKER HOOD 
CAPACITY LEVEL IN AUTOMATIC MODE 

 

The  automatic  regime  can  be  switched  on  with 
setting  of  switch  button  to  position  „A“  or  „AL“.  The 
cooker hood is running on the capacity level 1 during 
60  seconds,  the  sensor  is  heated  up  during  this 
period.  The  sensor  is  ready  for  operation  after 
heating  up.  The  sensor  thereafter  measures 
continuously  the  pollution  level  of  air  and  according 
to  the  measured  value  regulates  the  capacity  levels 
between 0 and 3. 
 

TURNING ON THE LIGHTS 

Light is ON when the control knob is in position “L”. 

 

TURNING OFF THE HOOD 

The hood is OFF when the control knob is in position 
“0”. 
 

THE COOKER HOOD IS EQUIPPED WITH 
THE SAFETY SWITCHING OFF FUNCTION 

 

When  the  switch  button  is  in  a  position  different  to 
„A“  or  „AL“  and  this  setting  will  be  not  changed 
during  a  period  of  one  week,  then  the  electronic 
control  of  hood  will  be  switched  off  automatically. 
The 

cooker 

hood 

is 

then 

in 

condition 

corresponding to switch button position 0. 
 

REMARK 

 

The  cooker  hood  electronics  regulates  the  capacity 
levels corresponding to gas and vapor concentration 
level measured  with the sensor. This  regulation can 
differ  from

 

expectations  derived  from  visual 

monitoring of vapor occurrence

At  recirculation  mode  the  air  in  the  room  is  not 
exchanged, so the humidity and pollution of air is not 