EN
2
MOUNTING OF COOKER HOOD
Unpack the appliance from packaging.
Drill holes for fasteners according the drawing 3.
Tap the fasteners to drilled holes.
Fix the appliance with provided screws throu
holes “G”.
IMPORTANT
The horizontal location of cooker hood should
be observed.
THE EXHAUSTION VERSION
At use of exhaustion version (see fig. 4) the
exhalations are led into the exhaustion opening
with the exhaustion hose, which is connected to
the cooker hood with a flange. The exhaustion
hose and the fastening clips should be bought
additionally.
The exhaustion is provided through the upper
outlet of the cooker hood, on which the
exhaustion hose should be connected and the
other end of hose should be connected into the
exhaustion opening. The diameter of exhaustion
hose should be the same as the diameter of
connecting flange
– e.g. Ø 150mm, or Ø 120mm
with a reduction piece (if you use connection hose
Ø 120mm, you will decrease exhaust capacity
and increase noise level).
MOUNTING OF EXHAUSTION VERSION
AND OF DECORATION CHIMNEY
Fasten with help of a hose clip on the hinged on
cooker hood the one end of exhaustion hose,
fasten the other end into the exhaustion opening.
Both parts (the upper C and lower B) of
decoration chimney, shifted one to the other,
place on the hinged on cooker hood.
Shift the upper part C into the required height,
mark the upper location and mark the fastening
openings of console (K).
Remove the decoration chimney and bore the
marked openings for the dowels.
Screw on the console (K) together with cover of
decoration chimney (M).
Fasten once more the both parts of decoration
chimney, shift out its upper part and fasten to the
console with two screws.
IMPORTANT
Remove protection foil from decoration chimney
not untill last assembly of decoration chimney!
IMPORTANT!
The carbon filter should not be installed in the
cooker hood at exhaustion version.
RECIRCULATION VERSION
A carbon filter and recirculation set should be
bought for the cooker hood in recirculation
version (fig. 9). The exhalations are exhausted
through the carbon filter.(fig. 1 (E)) The circulation
air with removed smell is led with exhausted hose
through air spreader to the ventilation openings in
upper part of decorative chimney to the room.
This version is used in cases, when there is no
waste air stack at disposal.
CAUTION!
The carbon filter should be installed in the
cooker hood at recirculation.
SETTING THE POWER LEVEL
Power level 1, 2, 3 is set by turning the control
knob.
If the control knob is set on 1L, 2L, 3L ventilation
and light is powered together.
TURNING ON THE LIGHTS
Light is ON when the control knob is in position “L”.
TURNING OFF THE HOOD
The hood is OFF when the control knob is in position
“0”.
MAINTENANCE AND CLEANING
At cleaning or maintenance switch the appliance
off from the power and this with disconnecting
from the socket or with switching off of
corresponding circuit breaker.
The regular maintenance and cleaning ensure the
efficiency, reliability and longer lifetime of cooker
hood.
Pay special attention to grease filter and to
carbon filter.
For cleaning of cooker hood do not use cleaning
articles containing aggressive substances mainly
chlorine and dissolvents.
GREASE METAL FILTER
The grease metal filter (F) catches the fat
particles.
The metal filter should be cleaned manually or in
dishwasher (at 65
C) with use of appropriate
detergents.
The filter can slightly change its color when
washed in dishwasher; nevertheless this fact has
no influence to its functionality.
Let the filter thoroughly dry after washing and
return it to cooker hood in dry state only.
CASSETTE CARBON FILTER
The carbon filter (E) absorbs the kitchen smell.
The carbon filter should be never washed!
INSTALLATION OF CASSETTE CARBON
FILTER
Disconnect the appliance from the power net.
Take out the grease filter (F) and fasten the
cassette carbon filter (E) to its internal side
– see
the picture.
Summary of Contents for DT6SY2B
Page 1: ......
Page 2: ......
Page 3: ...1 2 3 min 650 mm A F B C F E H 90 335 205 600 900 G...
Page 4: ...o 150 4 a b 5 K C B M...
Page 5: ...6 7 L 1L 2L 3L 3 2 1 0 250 95 349 420 600 900 270 min 485 max 955 150 8...
Page 11: ......
Page 12: ......