Simplex Armaturen & Systeme GmbH   

|

   Isnyer Straße 28 

|

  Phone  +49 75 66 94 08-0  

www.simplex-armaturen.de  

|

   88260 Argenbühl - Germany 

|

   Fax 

+49 75 66 94 08-75

EN

05/2019

VSH SUPER Compression Fittings

Technical Information 

|

 Installation Instructions

 

 

 

 

Remounting/multiple use of fittings

Existing connections can be removed and re-installed. 

The clamp ring fixed at its intended location is placed under 

tension when the union nut is tightened by hand. Then 

tighten 1/8 to 1/4 turn with a spanner.
The clamp ring can be removed by making an oblique saw 

cut (see Fig. 3), without damaging the pipe. Expand ring 

using a flat object and carefully removed it from the pipe.

Installation information

In table 2 the insertion depths are listed for planning and 

pre-fabrication (see Fig. 4).

Tables 3 and 4 show the flow resistance of the fittings at  

a water velocity of 0.75 m/s expressed in the equivalent pipe 

length per meter. For reduction fittings the values in table 4 

are to be added to the values in table 3.

Table 2

Fitting connection 

[ø mm]

Insertion depth A 

[mm]

6

13.5

8

14.5

10

16.5

12

18.5

15

21.5

16

22.5

18

22.5

20

22.5

22

23.0

28

23.5

35

30.0

42

35.5

54

39

12

15

22

28

15

0.2

-

-

-

22

0.3

0.2

-

-

28

-

0.3

0.1

-

35

-

0.4

0.2

0.1

Table 4

12

15

22

28

35

42

54

0.1

0.1

0.1

0.1

0.1

0.1

0.1

-

0.5

0.6

0.7

1.2

-

-

0.5

0.5

0.8

0.8

1.2

1.4

1.8

0.1

0.1

0.2

0.2

0.2

0.2

0.2

0.5

0.5

0.8

0.8

1.2

1.4

1.8

-

0.5

0.8

0.8

1.2

-

-

-

0.1

0.1

0.2

0.2

-

-

Table 3

A

A

B

C

D

E

A

B

C

D

E

Abb. 1

Abb. 2

Abb. 3

Abb. 4

A

A

B

C

D

E

A

B

C

D

E

Abb. 1

Abb. 2

Abb. 3

Abb. 4

Fig. 3

Fig. 4

All technical data is non-binding and does not represent guaranteed properties of the goods. The illustrations are symbolic and may differ from the respective product. 
Additional information is available upon request. It is the responsibility of the processor to select products in accordance with their properties. Installation instructions 
must be followed. Subject to technical amendments.