background image

PWS2000 Water Dispenser User Manual

 

C130-00049 OCT2013

 

Page 2

 

Notices & Safety Information 

Throughout this manual there are paragraphs set off by special headings. 

1.

Notice

 is used to emphasize installation, operation or maintenance information which is important, but does

not present any hazard to persons or property.

2.

Caution

 is used when failure to follow directions could result in damage to equipment or property.

3.

Warning

 is used to indicate a hazard which could cause injury or death if ignored.

The CAUTION and WARNING paragraphs are not meant to cover all possible conditions and situations that may 
occur. It must be understood that common sense, caution, and careful attention are conditions which cannot be 
built into the equipment. 

To ensure proper operation of your dispenser, carefully follow the instructions in this manual.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system.

Check and follow the applicable plumbing codes and ordinances when installing this equipment. Local codes
may  prohibit  the  discharge  of  acid  or  caustic  solutions  to  drain.  An  extra  solution  tank  should  be  used  to
neutralize the solution before discharging to drain. Follow local codes if they differ from this manual.

Regularly inspect the dispenser for water leaks. Water leaks can cause damage to home and property.

Only connect the power cord to a properly grounded outlet and do not use an extension cord.

Never pull the power plug from the outlet with a wet hand or allow the plug to get wet.

Keep the power cord out of heavy traffic areas. To avoid a fire hazard, never put the power cord under rugs,
near radiators, stoves or heaters.

Do not use a damaged power cord or plug. If damaged, a qualified service technician must replace it.

To meet European CE requirements, fasten the unit to the floor with the expansion bolt M6x60.

This  appliance  is  not  intended  for  use  by  persons  (including  children)  with  reduced  physical,  sensory  or
mental  capabilities,  or  lack  of  experience  and  knowledge,  unless  they  have  been  given  supervision  or
instruction  concerning  use  of  the  appliance  by  a  person  responsible  for  their  safety.    Children  should  be
supervised to ensure that they do not play with the appliance.

This product should not be disposed with other household wastes throughout the EU. To prevent  possible
harm  to  the  environment  or  human  health  from  uncontrolled  waste  disposal,  recycle  it  responsibly  to
promote the sustainable reuse of material resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was purchased.

Summary of Contents for PWS2000

Page 1: ...PWS2000 Water Dispenser User Manual C130 00049 OCT2013 Page 1 PWS2000 Water Dispenser User Manual ...

Page 2: ...ing to drain Follow local codes if they differ from this manual Regularly inspect the dispenser for water leaks Water leaks can cause damage to home and property Only connect the power cord to a properly grounded outlet and do not use an extension cord Never pull the power plug from the outlet with a wet hand or allow the plug to get wet Keep the power cord out of heavy traffic areas To avoid a fi...

Page 3: ...mbly Drawings 6 Installation 8 Position Level 8 Install Filtration 9 Establish Water Electrical Connections 10 Flush Filters 11 Sanitize Dispenser 11 Turn ON HOT COLD Switches 11 Record Installation Date 11 Operation 12 Service and Maintenance 13 General Maintenance 13 Sanitize Dispenser 13 UV System Bulb Replacement 13 Reset Leak Detection System 14 Reset HOT Tank Element 14 Troubleshooting 15 Te...

Page 4: ...nd dispenser spigot This system is used to inhibit the growth of bacteria by compromising their DNA structure When dispensing water you will notice a pulsating UV INSIDE light which simulates the UV light system activation The UV bulb is housed within a quartz sleeve which allows the UV light to pass through to the water This bulb should be replaced every 12 months and the quartz sleeve removed an...

Page 5: ... items Qty Item 1 PWS2000 Series Water Dispenser 1 Cup Holder 1 M4 X 30 Tamper proof Screw 1 M6 X 60 Expansion Bolt 1 User Manual 1 Inspect the outer panels for any damage which may have occurred during shipment 2 To inspect the interior remove the filtration service panel 3 Visually inspect for any wires tubing or fittings which may have come loose during shipment 4 Record the unit model and seri...

Page 6: ...t 22 Power Cord 3 Front Top Panel 13 Rear Service Panel 23 Thermostat for Cooling 4 Hot Water Pushbutton 14 ON OFF Switch HOT 24 Cold Tank Drain 5 Spigot 15 Main PCB Cover 25 RO Waste Drain 6 Drip Tray 16 Condenser 7 Filtration Service Panel 17 Hot Tank Drain 8 Front Lower Panel 18 Supply Inlet 9 UV Simulation Display 19 Adjustment Feet 10 Cold Water Pushbutton 20 ON OFF Switch COLD Top P ...

Page 7: ...r Manual C130 00049 OCT2013 Page 7 Figure 2 Exploded View Figure 3 Dimensions Leak Sensor Main Tank UV Chamber Compressor Filter Cartridge Filter Manifold Inlet Valve HOT Tank COLD Tank Redundant Level Sensor Primary Level Sensor ...

Page 8: ...W I TH C E S T A N DA R D S I T I S NE CE S S AR Y T O FA S TE N T HE UNI T T O TH E F L O O R T H E AP PL I AN CE S HO U LD N O T B E E XP O SE D T O D IR EC T S UN LI G H T HEA T S O UR C ES OR A N A M BIE N T AI R T EMP E RA T U RE A B O VE 9 0 F 3 2 C O R BE LO W 3 7 F 3 C O R S T R U C T U R A L D AM A GE M A Y O CC U R 4 To comply with CE standards it is necessary to fasten the unit to the f...

Page 9: ...sult with your local dealer on the best filtration solutions for the local water conditions and follow the manufacturer s instructions on their installation use and servicing Typical solutions include SED for the reduction of particulates CTO for chlorine taste and odor and RO for the filtration of waterborne microorganisms heavy metal and other inorganic contaminants The steps below apply to a ty...

Page 10: ...re provided for the HOT and COLD tanks 1 Connect a clean soft water supply to the unit Pressure must be 40 60psi 2 8 4 1 bar and at a temperature no more than 105 F 41 C 2 Flush the water supply feed until it runs clear before making connection to the dispenser C A U T I ON D O N O T C ONN E C T T HE D IS PEN SE R TO A W A TE R LI NE WH I CH EX C EED S 10 5 F 41 C A S S T R U C T U R A L D AM A GE...

Page 11: ...arry out a visual inspection for any water leaks 9 Lift the main storage tank lid taking care not to damage the level sensor 10 Wearing gloves and using a clean lint free cloth thoroughly wipe down the inside of the main storage tank 11 Let stand for ten minutes 12 Slowly turn ON the water supply 13 Depress the dispenser buttons alternate between HOT and COLD sides to allow the solution to run thr...

Page 12: ... Dispenser unpowered or ambient water ready to dispense n a COLD Illuminated Pushbutton Water chilling Dispenser unpowered or water chilled to preset temperature n a UV Simulation Light UV system ready UV system ready UV system active UV Fault Indicator UV bulb needs replacement UV system ready System fault i e leak short circuit ON only when user is in front of dispenser N O TE A CH IL D S A FE T...

Page 13: ...all tanks after long periods of non use 5 On RO models periodically inspect the flow restrictor to ensure it is clean an unrestricted W A RN IN G T A K E PR E CA U T I ON S WH E N D R AIN IN G THE HO T W A TE R SanitizeDispenser All tanks should be sanitized at regular intervals especially after a long period of non use This is best accomplished using a sanitization kit from the dispenser supplier...

Page 14: ...ll models of the PWS2000 Series Water Dispenser are fitted with a leak detect system which will generate an audible and visual warning upon detecting water at the base of the unit due to failed tubing or connections In addition the system will automatically close the incoming water supply valve to prevent further damage Normal operation will return once the source of the leak is removed ResetHOTTa...

Page 15: ...rn OFF the COLD switch for 4 hrs to melt ice inside tank No or low flow from HOT dispenser COLD is OK HOT water tank needs to be de scaled De scale HOT water tank If problem persists consult with your authorized service provider about adding a de scaling filter cartridge No or low flow from both HOT and COLD dispensers Filter cartridges may need changing Low pressure from water supply Change filte...

Page 16: ...erature Range 39 46 F 4 8 C Storage Capacity 1 Gallons 3 8 Liters Chilling Capacity Min 0 26 Gallon 1000 ml dispensed 40 F 5 C Min Max Water Pressure 40 60 psi 2 8 4 1 bar User Interface Electronic Controls Status Indicators Illuminated Pushbutton Power LED Adjustable Temperature Range No ON OFF Switch HOT and COLD Safety Features Child proof HOT Water Dispenser Standard Leak Detect with Auto Shut...

Page 17: ...PWS2000 Water Dispenser User Manual C130 00049 OCT2013 Page 17 Flow Diagrams Figure 10 Flow Diagram HOT COLD models Figure 11 Flow Diagram HOT AMBIENT and COLD models ...

Page 18: ...Diagram All models MC motor compressor H Heater SOL1 Inlet valve SOL2 HOT inlet valve SOL3 COLD inlet valve SWL compressor switch SWH Heater switch SW1 HOT dispenser switch SW2 COLD dispenser switch LD Water leak detector WLD Water level detector OV Low level control switch TH Temperature control switch ...

Page 19: ...093 HOT Tank Assembly 220AVC C030 00094 COLD Tank Assembly C010 00239 3G Tank Assembly C080 00007 Transformer 120VAC C080 00017 Transformer 220VAC C080 00023 Fuse 10A 120VAC C080 00006 Fuse 5A 220VAC C010 00045 Drip Tray Grill specify color C010 00044 Drip Tray specify color C010 00039 Filtration Service Panel specify color C030 00002 Left Side Panels specify color C030 00003 Right Side Panels spe...

Page 20: ...A at its sole discretion will determine whether to correct the defect or replace the unit or will request that the unit be returned to S A Provided a claim is based on a defect in materials or workmanship and provided the claim is made within the warranty period and provided the user has used and maintained the equipment in accordance with the manufacturer s instructions S A will replace the parts...

Reviews: