Installation Instructions Document No. 466-1574
23
Wiring the Control Panel
This section describes how to:
•
connect hardwire interior and exterior sirens (if
being installed)
•
connect hardwire sensors
•
connect garage door opener module
•
connect the power transformer
•
connect the backup battery
•
connect a phone line
Connecting Hardwire Interior Sirens
The following ITI interior sirens may be used with
this Control Panel:
•
LD105 Siren (13-374)
•
Phone Jack Siren (60-683)
Turn option 53 on for siren supervision. When option
53 is on and a hardwire exterior siren is not connected,
a 47k ohm resistor (two 47k ohm resistors are shipped
with the Control Panel) must be connected across the
positive and negative terminals. If a 47k ohm resistor
or a siren is not connected to the exterior siren termi-
nals, SYSTEM STATUS will say Module 1 failure.
Follow the siren installation instructions included
with the siren for siren specific EOL resistor connec-
tions. Only one hardwire interior siren may be con-
nected. See figure 2 below for a generalized wiring
connection.
Figure 2. Supervised Interior Siren Connections
Connecting a Hardwire Exterior Siren
The following ITI exterior siren may be used with this
Control Panel:
•
Hardwire Exterior Siren (13-046)
Turn option 53 on for siren supervision. When option
53 is on and a hardwire interior siren is not connected,
a 47k ohm resistor (two 47k ohm resistors are shipped
with the Control Panel) must be connected across the
positive and negative terminals. If a 47k ohm resistor
or a siren is not connected to the interior siren termi-
nals, SYSTEM STATUS will say Module 2 failure.
Wire sirens to be supervised by using a 4.7k ohm EOL
resistor, included with the siren.
Only one hardwire exterior siren may be connected.
See figure 3 below for wiring connections.
Note: Two 47k ohm resistors are included with the Con-
trol Panel. These should not be used for EOL resistors
when wiring sirens.
Figure 3. Supervised Exterior Siren Connections
Connecting Hardwire Sensors
This section shows how to wire hardwire sensors to
the Control Panel. For more programming informa-
tion on installing hardwire devices, “Programming
Sensors” on page 25. Wire sensors to be supervised
by using a 47k Ohm resistor (included with the Con-
trol Panel).
8988G48C.DS4
All inputs are Class II
power-limited circuits.
Hardwire
Input 1
or
Exterior
Siren
–
HARDWIRE INPUTS/SIREN
Hardwire
and
Power
Common
+
Hardwire
Input 2
or
Interior
Siren
–
47k
SIREN
8988G20E.DS4
HARDWIRE
EXTERIOR SIREN
PART NO. 13-046
RED
BLACK
All inputs are Class II
power-limited circuits.
AC POWER
Hardwire
Input 1
or
Exterior
Siren
–
HARDWIRE INPUTS/SIREN
Hardwire
and
Power
Common
+
Hardwire
Input 2
or
Interior
Siren
–
9 VAC
4.7k OHM
RESISTOR
47k OHM
RESISTOR