HUB PRO
IO
SOCKET
ENGLISH
DESCRIPTION
Once connected to the iO Simon Socket, (art. no. 1003x108-xxx), this device has WiFi antennas, Z-Wave, Low
Energy Bluetooth and Zigbee so you can use the iO Simon App to connect to a smart device (phone or tablet)
to register an iO Simon connected installation. It allows you to register and remotely control any iO Simon
device and other Z-Wave compatible devices in the same installation.
Plus, you can perform ON/OFF controls for plugged-in devices using local or wireless controls, and enjoy
extensive functions (timing, scheduling, power restrictions, power measurement, etc.), configurable using
the App.
This device is a Z-Wave Plus product with enabled security that can use Z-Wave Plus encrypted messages to
communicate with other Z-Wave Plus products with enabled security.
COMPLIANCE WITH Z-WAVE PROTOCOL
This product may be added to and managed in a Z-Wave network, working with Z-Wave certified devices and
applications from other manufacturers. All the devices that do not run on batteries will act as repeaters in the
Z-Wave network in order to increase network reliability.
* If the LED on the button turns on or blinks Blue, the other signals will not be displayed.
* If the button was pressed while locked, the LED button will blink red 3 times when released, at an interval of 0.5 seconds.
* Some of the functions or responses may change.
* This device may only be added or removed from a Z-Wave network if no other devices are added to its own Z-wave network.
USE OF KEYPAD AND ANSWERS
GROUP ASSOCIATION
1 (Lifeline)
“Lifeline”
3
COMMAND_CLASS_DEVICE_RESET_LOCALLY_NOTIFICATION. Sent to the
associated nodes when the device is removed from the Z-Wave network
ID
Name
Max. Nodes
Associated
CommandClass
To remove, it is necessary to use a tool
applied in the marked areas.
SIMON iO
This socket can NOT be replaced by an IO socket (art. no. 10002432-XXX,
1000246X-XXX). All the parts are exclusive for this article number.
Z-WAVE SPECIFICATIONS
CONTROLLED COMMAND CLASSES
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION GROUP INFORMATION_V3
COMMAND_CLASS_BASIC_V2
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_CENTRAL SCENE_V3
COMMAND_CLASS_CONFIGURATION_V4
COMMAND_CLASS_CRC 16 ENCAPSULATION_V1
COMMAND_CLASS_DEVICE RESET LOCALLY_1
COMMAND_CLASS_DOOR LOCK_V3
COMMAND_CLASS_INCLUSION CONTROLLER_V1
COMMAND_CLASS_MANUFACTURER SPECIFIC_V2
COMMAND_CLASS_METER_V3
COMMAND_CLASS_NOTIFICATION _V8
COMMAND_CLASS_SENSOR BINARY_V2
COMMAND_CLASS_SENSOR_MULTILEVEL_V11
COMMAND_CLASS_SWITCH BINARY_V2
COMMAND_CLASS_SWITCH MULTILEVEL_V4
COMMAND_CLASS_POWER LEVEL_V1
COMMAND_CLASS_SECURITY 0_V1
COMMAND_CLASS_SECURITY 2_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_THERMOSTAT FAN MODE_V4
COMMAND_CLASS_THERMOSTAT FAN STATE_VE
COMMAND_CLASS_THERMOSTAT MODE_V3
COMMAND_CLASS_THERMOSTAT OPERATING STATE_V2
COMMAND_CLASS_THERMOSTAT SET POINT_V3
COMMAND_CLASS_TIME PARAMETERS_V1
COMMAND_CLASS_TRANSPORT SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_WAKE UP_V2
COMMAND_CLASS_Z-WAVE PLUS INFO_V2
Z-WAVE DEVICE SPECIFICATION
Type of device CENTRAL_CONTROLLER
Generic type of device GENERIC_TYPE_STATIC_CONTROLLER
Specific type of device SPECIFIC_TYPE
Function type
ROLE_TYPE_CONTROLLER_CENTRAL_STATIC
CC BASIC MAPPING VALUES
The HUB Pro iO socket can
be controlled by a device that
supports Basic Command Class.
However, any Basic Command
Class received will be ignored and
no action will be taken.
INSTALLATION
Technical features
230 VAC
50Hz
(±10%)
16A
LED/CFL
5A
** INCLUSION_CONTROLLER_V1 AND CLASS_NW_INCLUSION are only available if the ZIPGW is an inclusion controller.
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_FIRMWARE_UPDATE_MD_V5
COMMAND_CLASS_INCLUSION_CONTROLLER_V1**
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_MULTI_CMD_V1
COMMAND_CLASS_NODE_PROVISIONING_V1
COMMAND_CLASS_NW_MGMT_BASIC_V2
COMMAND_CLASS_NW_INCLUSION**
COMMAND_CLASS_NW_INSTALLATION_MAINTENANCE_V1
COMMAND_CLASS_NW_MGMT_PROXY_V2
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_SECURITY_2_V1
COMMAND_CLASS_SUPERVISION_V1
COMMAND_CLASS_TRANSPORT_SERVICE_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
X
UNSAFE
INCLUSION
SAFE INCLUSION
SAFE
UNSAFE
SUPPORTED COMMAND CLASSES
100
32108-xxx
100
33108-xxx
SIMON, S.A.U.
Diputación, 390-392 / 08013 Barcelona
[email protected] Tel: (+34) 902109700
www.simonelectric.com
A991525
5-
12-
2019 1/5
DEVICE
STATUS
LED
FEEDBACK
EVENT
KEYPAD
ACTION
DEVICE
PERFORMANCE
Slow blue blinking on LED button
Fast white or green blinking on LED button
depending on charging status.
Fast blue blinking on LED button
Solid blue LED button
Charging ON with no power restrictions,
solid green LED button
Charging ON with power restrictions,
solid orange LED button
Charging OFF with or without power
restrictions, solid white LED button
Charging OFF for power excess, solid
red LED button
Beacon, LEDs 1-7 will adjust intensity based
on parameter 3
Charging ON
Charging OFF
Button locked
Initializing
Initializing
Wi-Fi
Wi-Fi enabled or
connected
Not pressed
Short press
(<2 seconds)
Long press for
10s<t <15 seconds
Long press for 2s<t<10s
All LEDs turn off
Long press for
15s<t <30 seconds
Long press for
t>30 seconds
Press button
Link with the iO
Simon app
Reset/Factory Reset
Restart device
Green LED button changes to solid
white LED button
White LED button changes to solid green LED
LED button blinks slowly 3 times in red, then
changes colour based on charging status
LED button blinks slowly before changing
to solid blue
The LED button performs a fast blinking
sequence in green, blue and purple while
the HUB PRO iO socket is being reset
Fast blue blinking LED button
until it is released
When button is released, the LED
button will remain blue; this indica-
tion stops once the user connects to
the iO HUB via the iO Simon App
If the power connected exceeds the
established limit, charging will deactivate
Restart the device’s WiFi interface
It will return to factory settings and
all Simon devices except batteries
are also set to the factory state
Charging deactivated
Charging enabled
Enabling Wi-Fi
Connected to
the iO SIMON
APP or a Z-Wave
network.
If the power connected exceeds
16 A, charging will deactivate