This device can only be included into
another controller there are no devices
included into its own Z-Wave network.
Some of the functions can be changed
depending
on
the
configuration
parameters.
If HUB iO is the primary controller for your
network, resetting it will result in the nodes
in your network being orphaned and it will be
necessary after the reset to exclude and re-
include all of the nodes in the network. If HUB iO
is being used as a secondary controller in the
network, use this procedure to reset this
controller only in the event that the network
primary controller is missing or otherwise
inoperable.
Z-WAVE COMPILANCE
This product can be included and operated in any
Z-Wave network with other Z-Wave certified
devices from other manufacturers and/or other
applications. All non-battery operated nodes
within the network will act as repeaters
regardless of vendor to increase reliability of the
network.
This product is a Security Enabled Z-Wave Plus
Controller that can manage both, secure and
unsecure Z-Wave devices.
Z-WAVE SPECIFICATIONS
ASOCIATION GROUPS
Group
Group 1 (Lifeline) -
> Name “lifeline”
Max. devices in
Group
3
Automatic
reports
COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load
changes state:
ON -> 0xFF
OFF -> 0x00
COMMAND_CLASS_METER_REPORT_V4
It is sent to the associated nodes when the power
consumed varies more than 10%
“Electric meter”, “Consumed”, “Watts”, Size 4,
Precision 1, Value (W)
COMMAND_CLASS_DEVICE_RESET_LOCALLY_
NOTIFICATION
The associated nodes are sent when the device is
deleted from the Z-Wave network
Group
Group 2 (Control) -
> Name “ctrl”
Max. devices in
Group
20
Automatic
reports
COMMAND_CLASS_BASIC_REPORT
It is sent to the associated nodes when the load
changes its state:
ON -> 0xFF
OFF -> 0x00
CONFIGURATIONS
NAME
SIZE VALUES
1 Association LED 1
0x00 -> (Default) Turns off the center LED
0xFF -> Turn on the center LED
2
Custom
consumption
limit
2
0x0000 -> (Default) Disables custom consumption limit
0x0001 - 0xFFFF -> Sets the power in Watts that is supported (once the load is over, it
is disconnected).
3 Beacon
1
0x00 -> (Default) Disables the beacon function.
0x01-0x63 (1-100%) -> Sets the intensity of the beacon LEDs.
10 Delay ON
1
0x00 -> (Default) Disables timing
11 Activation TIME
0x01-0x7F -> Sets a timing with a range of (1-127sec)
16 Delay OFF
0x80-0xFE -> Sets a timing with range of (1-127min)
12
Behavior of LED
in Repose
1
0x00 -> LED1 remains OFF and only informs of load state during 5 sec. after pressing
the button.
0xFF -> (Default) LED1 always shows the load state
13 Lock Input
1
0x00 -> (Default) Enables the pushbutton to control the load
0xFF -> Disables the action of the pushbutton on the load
15
Reset default
(Write Only)
2
0x9867 -> Parameters, Groups and Z-Wave status are restored to the default values.
0x4312 -> Parameters, with the exception of Long Pulse Lock, are reset to default
values.
17 PostReset State 1
0x00 -> After a reset the load starts Off
0xFF -> (Default) After a reset the load recovers the last value.
19 Pulse Action
1
0x00 -> (Default) TOGGLE (Default). A short press (t <2s) switches the
Load.
0x01 -> ON. A short press (t <2s) activates the load
0x02 -> OFF. A short press (t <2s) deactivates the load
20
Identify
(Write Only)
1
0xFF -> The central LED flashes for 5 seconds at a frequency of 0.1s
21
Load State
(Read Only)
2
[Byte 0] 0x00 -> Load is deactivated
0x01 -> Load is activated
[Byte 1] 0x00 -> Load is deactivated
0xFF -> Load is activated
27 Lock long press 1
0x00-> (Default) Long press works as described previously.
0xFF-> Neither Long press of 2s<t<30s does not perform any action.
Long press of t>30s Parameters, except Lock long press are restored to default
and device sends a Node Info.
Params that only have 0x00 or 0xFF as available values, supports Config Set with any 1
byte value. The device will Set the Param value to 0xFF if the written value is not 0x00.
All These configurations are not restored to default when device is removed from network.
COMMAND_CLASS_DEVICE_RESET_LOCALLY à
DEVICE_RESET_LOCALLY_NOTIFICATION will be sent to inform controller that node has been
removed from network, but the device will keep the current configurations.
To restore the configurations values, please perform one of these actions:
-
Use Command CONFIGURATION SET with default bit to 1 for each configuration
parameter.
-
Perform Reset Default Action via keypad pressing or Command Reset Default.
Z-WAVE DEVICE SPECIFICATION
Device Type
CENTRAL_CONTROLLER
Generic Device
Type
GENERIC_TYPE_STATIC_CONTROL
LER
Specific Device
Type
SPECIFIC_TYPE_PC_CONTROLLER
Role Type
ROLE_TYPE_CONTROLLER_CENTR
AL_STATIC
SUPPORTED COMMAND CLASSES
COMMAND_CLASS_ZWAVEPLUS_INFO_V2
COMMAND_CLASS_VERSION_V2
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_ASSOCIATION_GRP_INFO_V3
COMMAND_CLASS_POWERLEVEL_V1
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_DEVICE_RESET_LOCALLY_V1
COMMAND_CLASS_METER_V4
(Electric measurement; Watts, Voltage and Current
measurement allowed)
COMMAND_CLASS_APPLICATION_STATUS_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_SECURITY_V1
CONTROLLED COMMAND CLASSES
COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
COMMAND_CLASS_BASIC_V1
COMMAND_CLASS_SWITCH_BINARY_V1
COMMAND_CLASS_SWITCH_MULTILEVEL_V3
COMMAND_CLASS_ASSOCIATION_V2
COMMAND_CLASS_CONFIGURATION_V2
COMMAND_CLASS_METER_V4
COMMAND_CLASS_SECURITY_V1
COMMAND_CLASS_CRC_16_ENCAP_V1
COMMAND_CLASS_BATTERY_V1
COMMAND_CLASS_MULTI_CHANNEL_V4
COMMAND_CLASS_WAKE_UP_V2
COMMAND_CLASS_VERSION_V2
CC BASIC SET VALUES MAPPING
If Basic Set is received from a
Simon “Master” device selected
as trigger of an experience
Experience is performed
Other cases
Values are mapped as
“Power On/Off Switch”,
Activating/Deactivating the
socket Relay According the
Basic Set Value