background image

User manual - INDICATOR TRS-10a 

5. 

       PRINCIPLE OF OPERATION

The module type  

TRS-10a

  is equipped with 4 digits, seven segment, high bright LED

display. After switching the power on there in symbol "

- - - -

" on the display, informs user that

module is ready to work.

Display has two operation modes: 

basic mode called „

decimal mode

" in this manual – this mode allows direct displaying of

transmitted values as decimal digits, and  displaying defined warnings.

second mode called  „

byte mode

” in this manual allows to display user defined symbols 

Seven holding registers is used to service device: 01h to 05h, and 20h, 21h :

Register 01h  

- in

 

  "

decimal mode

" it is register of displayed value. All data written to this

register is displayed on the local display  as decimal value. Register accepts

values in U2 code of  range  -999 to 9999.  If user try to store value out of this

range, an error occur – device answers with exception code 03 (improper data

value), and displayed value will not change.
After switching power on, if display has been set to „

decimal mode

” then

register   01h   is   cleared   (to   0000h),   and   symbol  "

- - - -

"  is   showed   on   the

display.

While   normal   operation   storing   of   value   0000h   in   register   01h,   cause
displaying of  "

0.

", "

0.0

", "

0.00

" or "

0.000

" depends on  lower byte of register

02h (in decimal mode it is decimal point position and status).

- in „

byte mode

” this register drives directly segments of the display. Higher

byte   of   register   01   drives   decade   0   (most   right)   and     lower   byte   drives

segments   of  decade  1  (see  Figure 5.1). While  particular  bits  are  set   to 1

corresponding  segments  light (see  Tab.5.1). In this  mode register accepts

values of full range 0000h ÷ FFFFh.
After switching power on, if  display has been set to „

byte mode

” then register

01h is set to 4040h, and symbol  "

- - - -

" is showed on the display.

decade

no. 3

decade

no. 2

decade

no. 1

decade

no. 0

Figure 5.1. Decade and segments layout

9

Summary of Contents for TRS-10a

Page 1: ...l INDICATOR TRS 10a Firmware v 3 00 or higher Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes with...

Page 2: ...6 3 EXAMPLES OF QUERY ANSWER FRAMES 14 7 FORCING OF 0XFF ADDRESS 19 Explanation of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operat...

Page 3: ...ed off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate s...

Page 4: ...9 mm height red high bright Number of modules in 1 network maximum 127 Communication interface Baud rate RS 485 8N1 Modbus RTU 9600 bit sec Data memory non volatile memory EEPROM type Protection level...

Page 5: ...ducted with a disconnected power supply 4 1 UNPACKING After removing the unit from the protective packaging check for transportation damage Any transportation damage must be immediately reported to th...

Page 6: ...etc Carelessly executed assembly can increase the risk of electric shock Due to possible significant interference in industrial installations appropriate measures assuring correct operation of the uni...

Page 7: ...le in the network must be terminated with 100 150 Ohm resistor Figure 4 4 Connection of the module to the network 7 1 2 3 4 DATA DATA RS 485 Us Us 9 12V DC GND LED indicator force address 0xFF switch...

Page 8: ...nts available to the user Pay attention to the ambient temperature in the room where the unit is operating Excessively high temperatures cause faster ageing of the internal components and shorten the...

Page 9: ...re value out of this range an error occur device answers with exception code 03 improper data value and displayed value will not change After switching power on if display has been set to decimal mode...

Page 10: ...t decade If value 0003h will be written to reg 02h then value 0 124 will be displayed Additionally higher byte of register 02h decides about interpretation of reg 01h value If higher byte of register...

Page 11: ...ower byte of reg 03h as for changes of higer byte of reg 02h Changes of lower byte of reg 03h causes of automatical change of higher byte of reg 02H these two bytes are interdependent If display is in...

Page 12: ...module These addresses can be changed at any time using proper MODBUS commands or can be forced to be reset to 0xFF value using module internal momentary switch to enhance system installation process...

Page 13: ...ying status physical copy of higher byte of 02h register higher byte always 0 Byte mode always 0 can not be written 04h Yes 100h FFFFh Refresh period 05h Yes 00h 01h Operation mode 20h Yes 0h FFh Devi...

Page 14: ...address 1 All values are represent hexadecimal Field description ADDR Device address on Modbus network FUNC Function code REG H L Starting address address of first register to read write Hi and Lo byt...

Page 15: ...A H L CRC L H 01 06 00 20 00 02 09 C1 3 Turning on of decimal mode ADDR FUNC REG H L DATA H L CRC L H 01 06 00 05 00 00 99 CB The answer the same as the message ADDR FUNC REG H L DATA H L CRC L H 01 0...

Page 16: ...nt 6 Changing of decimal point position ADDR FUNC REG H L DATA H L CRC L H 01 06 00 02 00 02 A9 CB The answer the same as the message ADDR FUNC REG H L DATA H L CRC L H 01 06 00 02 00 02 A9 CB Display...

Page 17: ...s the message ADDR FUNC REG H L DATA H L CRC L H 01 06 00 05 00 01 58 0B Display content 10 Displaying of text Port Because in this mode segments are driven directly by bits of register 01h and 02h it...

Page 18: ...H L CRC L H 01 06 00 02 5C 73 50 EF Display content 11 Read of the registers 1 to 5 in one message example of reading a number of registries in one frame ADDR FUNC REG H L DATA H L CRC L H 01 03 00 01...

Page 19: ...s is implemented in Piggy Soft application as network configuration process To force address of device to value 0xFF turn module power supply and wait until it s LED indicator flashes every 10 second...

Page 20: ...SIMEX Sp z o o ul Wielopole 11 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: