8.
Displaying of Warning
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
02
20
02
B0
0B
The answer (the same as the message):
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
02
20
02
B0
0B
Display content:
9.
Switching to „byte mode”
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
05
00
01
58
0B
The answer (the same as the message):
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
05
00
01
58
0B
Display content:
10.
Displaying of text ”Port”:
Because in this mode segments are driven directly by bits of register 01h and 02h, it is
necessary to determine correct values of register 01h and 02h.
Letter “P” is equal to bit combination : 01110011 = 73h
Letter “o” is equal to bit combination : 01011100 = 5Ch
Letter “r” is equal to bit combination : 01010000 = 50h
Letter “t” is equal to bit combination : 01111000 = 78h
ADDR
FUNC
REG H,L
DATA H,L
CRC L,H
01
06
00
01
78
50
FA
36
17