User manual - POWER SUPPLY TRS-09a 

- In the case of the unit being fitted with separable clamps they should be inserted 
into appropriate connectors in the unit, even if they are not used for any 

connections. 

- Unused clamps (marked as n.c.) must not be used for connecting any connecting 

cables (e.g. as bridges), because this can cause damage to the equipment or 
electric shock. 

- If the unit is equipped with housing, covers and sealing packing, protecting 
against water intrusion, pay special attention to their correct tightening or clamping. 

In the case of any doubt consider using additional preventive measures (covers, 
roofing, seals, etc.). Carelessly executed assembly can increase the risk of electric 

shock.     

- After the installation is completed do not touch the unit’s connections when it is 

switched on, because it carries the risk of electrical shock. 

Due to possible significant interference in industrial installations appropriate measures 
assuring correct operation of the unit must be applied.  To avoid the unit of improper 
indications keep recommendations listed below.

-

Avoid common (parallel) leading of signal cables and transmission cables together with 
power supply cables and cables controlling induction loads (e.g. contactors). Such cables 

should cross at a right angle.

-

Contactor coils and induction loads should be equipped with anti-interference protection 
systems, e.g. RC-type.

-

Use of screened signal cables is recommended. Signal cable screens should be 

connected to the earthing only at one of the ends of the screened cable.  

-

In the case of magnetically induced interference the use of twisted couples of signal cables 
(so-called “spirals”) is recommended. The spiral (best if shielded) must be used with RS-

485 serial transmission connections.

-

In   the   case   of   interference   from   the   power   supply   side   the   use   of   appropriate   anti-
interference filters is recommended. Bear in mind that the connection between the filter 

and the unit should be as short as possible and the metal housing of the filter must be 
connected to the earthing with largest possible surface. The cables connected to the filter 

output must not run in parallel with cables with interference (e.g. circuits controlling relays 
or contactors).

Connections of power supply voltage and measurement signals are executed using the 

screw connections inside of the unit’s housing (Figure 4.2 - 4.4).

Figure 4.2.  Method of cable insulation replacing  and cable terminals

7

m

ax

m

m

6-7 mm

Summary of Contents for TRS-09a

Page 1: ...6 User manual POWER SUPPLY TRS 09a Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes without prior n...

Page 2: ...n of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operation of the device Not complying with the guidelines denoted by this symbol may...

Page 3: ...ched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate...

Page 4: ...efficiency max 200 mA Control voltage 7V 12V DC max 2mA Protection level IP 65 ABS casing Housing type Housing material Housing dimensions L x W x D without glands with glands wall mounted ABS 110 x 8...

Page 5: ...etwork voltage corresponds to the nominal voltage stated on the unit s identification label The load must correspond to the requirements listed in the technical data All installation works must be con...

Page 6: ...circuit breaker located near the unit In the case of using a monopolar fuse it must be mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the...

Page 7: ...ransmission cables together with power supply cables and cables controlling induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equip...

Page 8: ...nes connectors GND GND of supply output and control input Figure 4 4 Connection of TRS 09a module to the network 8 5 8 7 6 4 3 1 2 DATA DATA RS 485 ctrl GND 12V out shield 230V AC J1 J2 LED indicator...

Page 9: ...network at the same time When power supply of first TRS 09a module is turned off then following power supply modules will be turned off sequentially Figure 4 6 Cascade of power supply modules TRS 09a...

Page 10: ...rked with this symbol should not be placed in municipal waste Please check local regulations for disposal and electronic products 5 SELECTION OF OPERATION MODE The selection of operation mode can be d...

Page 11: ...User manual POWER SUPPLY TRS 09a Figure 5 1 Selection of operation mode 11 5 8 7 6 4 3 1 2 J1 J2 Operation mode selection jumpers J1 J2 J1 J2 J1 J2 Stand alone mode Externally controlled mode or...

Page 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: