User manual - POWER SUPPLY TRS-09a 

4.4. 

 

     MAINTENANCE

 

 

The unit does not have any internal replaceable or adjustable components available to the 

user.   Pay   attention   to   the   ambient   temperature   in   the   room   where   the   unit   is   operating. 
Excessively high temperatures cause faster ageing of the internal components and shorten the 

fault-free time of unit operation. 
In cases where the unit gets dirty do not clean with solvents. For cleaning use warm water with 

small amount of detergent or in the case of more significant contamination ethyl or isopropyl 
alcohol. 

Using any other agents can cause permanent damage to the housing.

Product marked with this symbol should not be placed in municipal waste. Please 
check local regulations for disposal and electronic products.

5. 

       SELECTION OF OPERATION MODE

 

 

The selection of operation mode can be done by proper jumper settings (see Figure 5.1):

externally controlled mode 

 

 

:  

 {J1} 

open , 

{J2}

 open or short

This configuration allows to remote control of the module using it's control input (voltage 

7÷12V connected to { 

ctrl

 } terminal). If control input is not connected, or it's voltage is to low, 

module output voltage is turned off  - voltage between terminals  { 

+12V out 

} and { 

GND

 } will 

drop to 0V.

Stand alone mode

 

 

:  

{J1}

 short, 

{J2}

 open

This configuration allows stand alone mode of  module operation. Module is independent 

of external signal  

{ ctrl }

. Power supply module is permanently turned on  -  voltage between 

terminals  {

 +12V

 

out 

} and { 

GND

 }  is about 11.5 V. 

10

Summary of Contents for TRS-09a

Page 1: ...6 User manual POWER SUPPLY TRS 09a Designed for TRS system Read the user s manual carefully before starting to use the unit or software Producer reserves the right to implement changes without prior n...

Page 2: ...n of symbols used in the manual This symbol denotes especially important guidelines concerning the installation and operation of the device Not complying with the guidelines denoted by this symbol may...

Page 3: ...ched off and disconnected from the power supply prior to starting installation of troubleshooting in the case of malfunction Neighbouring and mating equipment must meet the requirements of appropriate...

Page 4: ...efficiency max 200 mA Control voltage 7V 12V DC max 2mA Protection level IP 65 ABS casing Housing type Housing material Housing dimensions L x W x D without glands with glands wall mounted ABS 110 x 8...

Page 5: ...etwork voltage corresponds to the nominal voltage stated on the unit s identification label The load must correspond to the requirements listed in the technical data All installation works must be con...

Page 6: ...circuit breaker located near the unit In the case of using a monopolar fuse it must be mounted on the phase cable L The power supply network cable diameter must be selected in such a way that in the...

Page 7: ...ransmission cables together with power supply cables and cables controlling induction loads e g contactors Such cables should cross at a right angle Contactor coils and induction loads should be equip...

Page 8: ...nes connectors GND GND of supply output and control input Figure 4 4 Connection of TRS 09a module to the network 8 5 8 7 6 4 3 1 2 DATA DATA RS 485 ctrl GND 12V out shield 230V AC J1 J2 LED indicator...

Page 9: ...network at the same time When power supply of first TRS 09a module is turned off then following power supply modules will be turned off sequentially Figure 4 6 Cascade of power supply modules TRS 09a...

Page 10: ...rked with this symbol should not be placed in municipal waste Please check local regulations for disposal and electronic products 5 SELECTION OF OPERATION MODE The selection of operation mode can be d...

Page 11: ...User manual POWER SUPPLY TRS 09a Figure 5 1 Selection of operation mode 11 5 8 7 6 4 3 1 2 J1 J2 Operation mode selection jumpers J1 J2 J1 J2 J1 J2 Stand alone mode Externally controlled mode or...

Page 12: ...SIMEX Sp z o o ul Wielopole 7 80 556 Gda sk Poland tel 48 58 762 07 77 fax 48 58 762 07 70 http www simex pl e mail info simex pl...

Reviews: