Register
Write
Range
Register description
4Ch
6
Yes
0 ÷ 999
“toFF”
parameter in
“rEL4”
menu, expressed in tenth of seconds
or tenth of minutes depend on
“unit”
parameter - register no. 4Dh)
4Dh
6
Yes
0 ÷ 1
“unit”
parameter in
“rEL4”
menu:
0
- seconds;
1
- minutes
4Eh
6
Yes
0 ÷ 2
“AL”
parameter in
“rEL4”
menu:
0
- no changes;
1
- on;
2
- off
4Fh
6
Yes
-999 ÷ 9999 “
SEt2
” parameter in “
rEL4
” menu, no decimal point included
50h
Yes
0 ÷ 1
“
modE
” parameter in “
HOLd
” menu (type of detected changes):
0
- peaks;
1
- drops
51h
Yes
0 ÷ 9999
“
PEA
” parameter in “
HOLd
” menu (minimum detectable change, no
decimal point included)
52h
Yes
0 ÷ 199
“
timE
” parameter in “
HOLd
” menu,
maximum peaks' (or drops')
display time expressed in seconds
53h
Yes
0 ÷ 1
“
HdiS
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
54h
6
Yes
0 ÷ 1
“
H r1
” parameter in “
HOLd
” menu
:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
55h
6
Yes
0 ÷ 1
“
H r2
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
56h
6
Yes
0 ÷ 1
“
H r3
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
57h
6
Yes
0 ÷ 1
“
H r4
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
58h
1
Yes
0 ÷ 1
“
HOUt
” parameter in “
HOLd
” menu:
0
- “
rEAL
” mode ;
1
- “
HOLd
” mode
70h
5
Yes
-999 ÷ 1999
The value of „
X
” coordinate of point
no. 1
of the user defined
characteristic, expressed in 0.1%
71h
5
Yes
-999 ÷ 9999
The value of „
Y
” coordinate of point
no. 1
of the user defined
characteristic, no decimal point included
72h
5
÷ 95h
5
Further pairs of „
X
” - „
Y
” coordinates of points
no. 2
÷
19
of the
user defined characteristic
96h
5
Yes
-999 ÷ 1999
The value of „
X
” coordinate of point
no. 20
of the user defined
characteristic, expressed in 0.1%
97h
5
Yes
-999 ÷ 9999
The value of „
Y
” coordinate of point
no. 20
of the user defined
characteristic, no decimal point included
A0h
1
Yes
0 ÷ 3
“
Omod
” parameter in “
OUtP
” menu (current output mode)
0
-
current output disabled
;
1
-
current output enabled
with 4
÷
20mA
mode;
2
-
current output enabled with 0÷20mA mode
;
3
-
current output controlled via RS-485 interface
A1h
1
Yes
-999 ÷ 9999 “
OUtL
” parameter in “
OUtP
” menu,
no decimal point included
A2h
1
Yes
-999 ÷ 9999 “
OUtH
” parameter in “
OUtP
” menu,
no decimal point included
A3h
1
Yes
0 ÷ 999
“
Lo r
” parameter in “
OUtP
” menu, expressed in 0.1%
A4h
1
Yes
0 ÷ 199
“
Hi r
” parameter in “
OUtP
” menu, expressed in 0.1%
51