User manual - METER SRT-94-XA
Register Write
Range
Register description
3Ch
Yes
0 ÷ 999
“toFF”
parameter in
“rEL2”
menu, expressed in tenth of
seconds or tenth of minutes depend on
“unit”
parameter -
register no. 3Dh)
3Dh
Yes
0 ÷ 1
“unit”
parameter in
“rEL2”
menu:
0
- seconds;
1
- minutes
3Eh
Yes
0 ÷ 2
“AL”
parameter in
“rEL2”
menu:
0
- no changes;
1
- on;
2
-
off
3Fh
Yes
-999 ÷ 9999
“
SEt2
” parameter in “
rEL2
” menu, no decimal point included
40h
Yes
-999 ÷ 9999
“
SEtP
” parameter in “
rEL3
” menu, no decimal point included
41h
Yes
-999 ÷ 999
“
HySt
” parameter in “
rEL3
” menu, no decimal point included
42h
Yes
0 ÷ 5
“
modE
” parameter in “
rEL3
” menu:
0
- “
noAC
” mode;
1
- “
on
” mode;
2
- “
oFF
” mode;
3
- “
in
” mode;
4
- “
out
” mode;
5
- “
modb
” mode
43h
Yes
0 ÷ 999
“t on”
parameter in
“rEL3”
menu, expressed in tenth of
seconds or tenth of minutes depend on
“unit”
parameter -
register no. 45h)
44h
Yes
0 ÷ 999
“toFF”
parameter in
“rEL3”
menu, expressed in tenth of
seconds or tenth of minutes depend on
“unit”
parameter -
register no. 45h)
45h
Yes
0 ÷ 1
“unit”
parameter in
“rEL3”
menu:
0
- seconds;
1
- minutes
46h
Yes
0 ÷ 2
“AL”
parameter in
“rEL3”
menu:
0
- no changes;
1
- on;
2
-
off
47h
Yes
-999 ÷ 9999
“
SEt2
” parameter in “
rEL3
” menu, no decimal point included
48h
Yes
-999 ÷ 9999
“
SEtP
” parameter in “
rEL4
” menu, no decimal point included
49h
Yes
-999 ÷ 999
“
HySt
” parameter in “
rEL4
” menu, no decimal point included
4Ah
Yes
0 ÷ 5
“
modE
” parameter in “
rEL4
” menu:
0
- “
noAC
” mode;
1
- “
on
” mode;
2
- “
oFF
” mode;
3
- “
in
” mode;
4
- “
out
” mode;
5
- “
modb
” mode
4Bh
Yes
0 ÷ 999
“t on”
parameter in
“rEL4”
menu, expressed in tenth of
seconds or tenth of minutes depend on
“unit”
parameter -
register no. 4Dh)
4Ch
Yes
0 ÷ 999
“toFF”
parameter in
“rEL4”
menu, expressed in tenth of
seconds or tenth of minutes depend on
“unit”
parameter -
register no. 4Dh)
4Dh
Yes
0 ÷ 1
“unit”
parameter in
“rEL4”
menu:
0
- seconds;
1
- minutes
4Eh
Yes
0 ÷ 2
“AL”
parameter in
“rEL4”
menu:
0
- no changes;
1
- on;
2
-
off
4Fh
Yes
-999 ÷ 9999
“
SEt2
” parameter in “
rEL4
” menu, no decimal point included
34
Summary of Contents for SRT-94-XA