User manual - METER SRP-94-XC
In the most cases parameter
”rESP”
should be set to
”Std”
(no additional delay).
Unfortunately for some third party RS-converters
”rESP”
should be adjusted
experimentally. Table 7.1 contains most frequently used values.
”bAud” parameter
“38.4”
“57.6”
“115.2”
”rESP” parameter
“ 10c”
“ 20c”
“ 50c”
Tab.7.1.
Settings of
”rESP”
parameter
7.3.9.
”Edit”
paramet
er
This parameter allows to change the edition mode of numerical parameters:
”dig”
- the change to “by digit” mode,
”Slid”
- slide change mode.
7.3.10.
”dEFS”
parameter
This setting allows to restore the factory settings of the device. To get the access to this
option special password is required: „5465”, next the device displays acknowledge question
„SEt?”
. Press
[ENTER]
to acknowledge the restoring of factory settings or
[ESC]
to cancel.
7.3.11.
”SErv” menu
This menu contains the parameters for authorized service only. To enter this menu
proper service password must be entered. Improper settings can causes of damage of the
device.
31
i
Summary of Contents for SRP-94-XC
Page 50: ...User manual METER SRP 94 XC 50...
Page 51: ...User manual METER SRP 94 XC 51...