Simer PORTABLE UTILITY/SPRINKLER PUMP 2825SS Owner'S Manual Download Page 2

Safety  

2

For parts or assistance, call Simer Customer Service at 

1-800-468-7867

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol. When you see this 
symbol on your pump or in this manual, look for 

one of the following signal words and be alert to the 
potential for personal injury.

warns about hazards that will cause seri-

ous personal injury, death or major property damage if 
ignored.

warns about hazards that can cause seri-

ous personal injury, death or major property damage if 
ignored.

warns about hazards that will or can cause 

minor personal injury or property damage if ignored.
The label NOTICE indicates special instructions which 
are important but not related to hazards.
Carefully read and follow all safety instructions in this 

manual and on pump.
Keep safety labels in good condition.  

Replace missing or damaged safety labels.
California Proposition 65 Warning

This product and related accessories con-

tain chemicals known to the State of California to cause 
cancer, birth defects or other reproductive harm.

GENERAL SAFETY

1.  To avoid risk of serious bodily injury and property 

damage, read the safety instructions carefully before 

installing this pump.

2.  Follow local and/or national plumbing  and electrical 

codes when installing the pump.

3. 

Hazardous Pressure. The pump body 

may explode if used as a booster pump unless a 

relief valve capable of passing the full pump flow at 

60 PSI (414 kPa) is installed. Never run the pump 

dry. To do so can damage internal parts, overheat 

pump (which can cause burns to people handling or 

servicing pump), and will void warranty!

4. 

Risk of fire or explosion. To avoid risk 

of fire and explosion, Pump Water Only with this 

pump. Do not use this pump in an atmosphere that 

might contain flammable fumes or vapors.

5. 

Burn Hazard. If water is trapped in the 

pump during operation it may turn to steam. Trapped 

steam can lead to explosion and burns. Never run the 

pump with the outlet closed or obstructed. 

6.  If used with a well for potable water, always dis in fect 

the well and test the water for purity before using. 

Check with your local health de part ment for testing 

pro ce dures.

7.  Complete pump and piping must be protected against 

freezing. Freezing will cause damage and void the 

warranty.

8.  This pump is not designed, nor intended, for the 

pumping of chemicals or corrosive liquids. Pump 

water only with this pump.

9.  Do not run pump dry. If the pump is dry, damage 

will result and void the warranty.

ELECTRICAL SAFETY

The pump is supplied with a 3-conductor ground-

ing type cord. Connect only to a properly ground-

ed, GFCI protected outlet. Do not lift the pump by the 

electrical cord.

Match the motor voltage and the power supply 

voltage. The supply voltage must be /- 10% 

of the motor nameplate voltage.  Incorrect voltage can 

cause fire or seriously damage the motor and will void 

the warranty. If in doubt, consult a licensed electrician.

The pump is non-submersible. Keep the motor dry 

at all times.  Do not wash the motor.  Do not 

immerse.  Protect the motor from wet weather.

If using an extension cord, use only a UL approved 

indoor/outdoor, 3-wire, grounding type cord.  Do 

not allow any part of the cord or the receptacle ends to 

sit in water or in damp locations.

Unplug the pump before servicing. To avoid fatal 

shocks, proceed as follows if the pump needs  

servicing.

A. Disconnect the power  

  to the pump outlet box  

  before pulling the  

  pump plug. Modern  

  motors are designed  

  to operate at high  

  temperatures. To avoid  

  burns when servicing  

  pump, allow it to cool  

  for 20 minutes after  

  shut-down before  

 handling.
B.  Take extreme care  

  when changing fuses.  

  To reduce the chanc of 

fatal electrical shocks, DO 

NOT stand in water or put 

your finger in the fuse socket.

C.  Ground the pressure switch or motor before before 

running this pump.

D.  Plug pump into a Ground Fault Circuit Interrupter 

(GFCI) protected grounded outlet only.

WARNING

Hazardous voltage. Can 

shock, burn, or cause death.
Ground pump before connecting 

to power supply. Disconnect 

power before working on pump, 

motor or tank.

WARNING

Hazardous pressure!  

Install pressure relief  

valve in discharge pipe.
Release all pressure on  

system before working on  

any component.

Summary of Contents for PORTABLE UTILITY/SPRINKLER PUMP 2825SS

Page 1: ...ce Call 1 800 468 7867 English Pages 2 7 Installation Fonctionnement Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages...

Page 2: ...for potable water always dis in fect the well and test the water for purity before using Check with your local health de part ment for testing pro ce dures 7 Complete pump and piping must be protected...

Page 3: ...O NOT return a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If yo...

Page 4: ...is completes the well plumbing for your new shallow well jet pump Please go to Page 6 for discharge pipe and tank connections BOOSTING CITY WATER PRESSURE Hazardous pressure Never run the pump against...

Page 5: ...gth of the suction hose and the height of the pump above water PREPARING TO START THE PUMP REFER TO FIGURE 5 Risk of burns Never run pump dry Running the pump without water may cause the pump to overh...

Page 6: ...ine with soapy water or shaving cream 3 Leaking foot valve 3 Replace foot valve 4 Pipe size is too small 4 Re pipe using size of suction and discharge ports on pump Pump has lost prime through In inst...

Page 7: ...Pump Body 1 111P1190 8 Flange 1 101P1290 9 Intermediate Support 1 721S4460 10 Handle with Handle Grip 1 751S8960 11 Washer Handle 1 121P1500 12 Screw Handle 1 121P1600 13 Lock Nut Handle 1 121P0020 14...

Page 8: ...t avant d utiliser l eau la faire analyser pour s assurer de sa puret Pour proc der l analyse de l eau s adresser au Service de sant de la municipalit 7 La pompe et les tuyauteries doivent tre prot g...

Page 9: ...illant Communiquer avec le service la client le de SIMER Les pompes d eaux d gout qui ont t utilis es puis retir es pr sentent un risque de contamination En cas de d faillance de la pompe d eaux d gou...

Page 10: ...syst me S assurer que tous les raccords du tuyau d aspiration sont bien tanches aussi bien l air qu l eau Si le tuyau d aspiration aspire de l air la pompe ne pompera pas l eau du puits 3 R gler la h...

Page 11: ...lle ris que de surchauffer ses joints risquent d tre endommag s et les personnes qui la manipuleront risquent de se br ler Remplir la pompe d eau avant de la d marrer Pression dangereuse Risque d expl...

Page 12: ...du tuyau d aspiration 3 Parce que le clapet de pied fuit 3 Remplacer le clapet de pied 4 Parce que le diam tre du tuyau 4 Remplacer le tuyau par un dont le diam tre est le m me que celui est trop peti...

Page 13: ...101P1290 9 Support interm diaire 1 721S4460 10 Poign e 1 751S8960 11 Rondelle de la poign e 1 121P1500 12 Vis de la poign e 1 121P1600 13 crou de la poign e 1 121P0020 14 D flecteur d eau 1 102P0540 1...

Page 14: ...na prueba de la pureza de agua antes de usarla Verifique los procedimientos de prueba con su depar tamento de sanidad local 7 Tanto la bomba como los tubos deben estar protegidos contra heladas Las he...

Page 15: ...loacales NO devuelva una bomba cloacal que se haya instalado a su tienda minorista Comun quese con el Departamento de Atenci n al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y s...

Page 16: ...completar la tuber a del pozo para su nueva bomba de chorro para pozos poco profundos Pase a la p gina 6 para la informaci n sobre las conexiones de la tuber a de descarga y del tanque REFUERZO DE LA...

Page 17: ...ocar sobrecalentamiento puede da ar el sello y posiblemente provoque quemaduras a las perso nas que la est n manipulando Llene la bomba con agua antes de encenderla Presi n peligrosa Nunca haga marcha...

Page 18: ...bos del tama o de los orificios de demasiado peque o aspiraci n y de descarga en la bomba La bomba ha perdido cebadura debido a En instalaciones que ya est n en uso 1 Fugas de aire 1 Verifique todas l...

Page 19: ...Brida 1 101P1290 9 Soporte intermedio 1 721S4460 10 Manija 1 751S8960 11 Arandela Manija 1 121P1500 12 Tornillo Manija 1 121P1600 13 Contratuerca Manija 1 121P0020 14 Deflector del agua 1 102P0540 15...

Page 20: ......

Reviews: