Simer Ace-In-The-Hole A5000-01 Owner'S Manual Download Page 10

For parts or assistance, call Simer Customer Service at 

1-800-468-7867 / 1-800-546-7867

Troubleshooting

10

SYMPTOM

PROBABLE CAUSE(S)

CORRECTIVE ACTION

The sump is empty and the 

Defective Float Switch. 

Disconnect the float switch from the control panel.  

float switch is down, but

If the pump stops the float switch needs to be replaced. 

the pump won’t shut off.

Defective Control Panel.

If the pump does not stop, replace the control panel.

Pump won’t run.

Float Switch is hung up and  

Check that the float switch is free to swing up and down

can’t swing through its 

through its entire arc.

entire arc.
Loose electrical connection.

Check all of the connections.

Defective battery or battery  

Check for a low or defective battery. The back-up pump will

voltage is too low 

not run if battery voltage is less than 8.2 Volt.

(below 8.2 Volts).

Motor hums but pump 

Defective battery or battery is 

Check for a low or defective battery. Confirm positive and

won’t run.

not charged enough.

negative wires are connected correctly.

Pump runs but pumps very 

The check valve, between   

Make sure a check valve is installed correctly between 

little or no water. 

the primary pump discharge   

the primary pump discharge and Backup Sump Pump 

and the backup pump, is   

discharge pipe and is functioning correctly.

installed backwards or not 
functioning  correctly.
Obstructed anti-airlock hole.

Clean out the anti-airlock hole in the pump body.

The pump discharge pipe is 

Check for an obstruction in discharge pipe.

obstructed.
The discharge pipe length or

See Table IV for pumping heights. Increase pipe size.

height is too long for pump’s 
capacity.
The battery is not charged 

Check for a low or defective battery. An extended power

properly or is defective.

outage may have depleted the battery.

The positive and negative  

Reverse the positive (+) and negative (-) wires.

wires are reversed on battery.

Pump cycles too frequently.

Tether length is too short on  

The correct tether length is 3-1/2”. Adjust the tether length 

the automatic float switch. 

accordingly.

The check valve, between the 

The primary pump check valve located between the  

primary pump discharge and  

discharge of primary pump and the Backup Sump Pump   

the backup pump, is not  

tee is not installed or not working properly. Install or repair 

installed properly or not  

as required. Confirm that the check valve is installed with  

functioning correctly.

the arrow pointing “up”. If the check valve is installed  
backward, replace it with a new one.

Excessive water is coming into

Call a plumber.

the sump pit.

Summary of Contents for Ace-In-The-Hole A5000-01

Page 1: ...t Pi ces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 1 800 468 7867 Fran ais Pages 12 21 Instalaci n Operaci n Piezas Para mayor informaci n sobre el...

Page 2: ...ubricate it 6 Keep the battery charger and battery box at least 18 off of the floor and in a dry cool well ventilated area SIMER warrants to the original consumer purchaser Purchaser of its products t...

Page 3: ...ce In The Hole is not a substitute for your primary sump pump It is designed to temporarily back up your primary sump pump during a power outage or other problem which prevents normal operation of the...

Page 4: ...ooding Do not turn the pump on until all the fittings are glued and the glue has dried Loose fit tings can explode off of pipes and cause personal injury and flooding NOTICE This pump is intended for...

Page 5: ...piping from the backup pump s check valve to the water disposal area or into the primary pump discharge pipe If sharing a common discharge pipe install a check valve between the pri mary pump and the...

Page 6: ...9 Neatly coil any excess transformer cord and tape it near the transformer NOTICE When the transformer is first plugged in all lights will come on for 3 seconds then either the green System Ready ligh...

Page 7: ...Table II at a rate of once Charging Errors per second with the alarm on TABLE III CONTROL PANEL LIGHTS ALARM SUMMARY All lights flashing Blown fuse at a rate of once Battery leads are reversed per se...

Page 8: ...ed light will again turn on 3 To disable the alarm while working on the system perform an entire system reset as explained in step 5 in the above section After either the green or yellow light have co...

Page 9: ...d charging cycles may cause early plate failure in the battery Use only a battery of the type and size recommended so it will fit in the battery box maximum size 12 75 long 8 wide and 9 5 high includi...

Page 10: ...rge the primary pump discharge and Backup Sump Pump and the backup pump is discharge pipe and is functioning correctly installed backwards or not functioning correctly Obstructed anti airlock hole Cle...

Page 11: ...7 8 Fus e F u s e F u s e 3 Key Part Part No Description No 1 Hinged Battery Box 404 117 2 Control Panel C014 01 3 Float Control Switch Kit C015 4 Clamp Bracket Kit C003 5 Rubber Hose Coupling and Cla...

Page 12: ...cer une pompe de puisard principale Risque d incendie pouvant causer des blessures graves des dommages mat riels voire la mort Pour viter une explosion ou un incendie ne pas approcher de la batterie d...

Page 13: ...ar un technicien qualifi RENSEIGNEMENTS G N RAUX Cette pompe ne remplace pas une pompe de puisard princi pale Elle est con ue en tant que pompe de secours temporaire en cas de panne de courant ou de t...

Page 14: ...le et 2 5 cm 1 po au dessus du niveau de l eau o la pompe de puisard principale se met en marche rep rer l emplace ment de la pompe de secours Lorsque l installation sera termin e le fond de la pompe...

Page 15: ...e et de la pompe de secours pour emp cher tout d bit contre courant de la pompe de secours dans la pompe de puisard principale Se reporter la Figure 5 9 Avec des colliers attacher le cordon lectrique...

Page 16: ...branch pour la premi re fois tous les t moins s allumeront pendant 3 secon des puis soit le t moin vert System Ready Syst me pr t soit le t moin jaune Charging AC Power Recharge Courant alternatif s a...

Page 17: ...lum et l alarme retentit de fa on continue Tous les t moins Se reporter au TABLEAU II clignotent la cadence Erreurs de charge d une fois par seconde et l alarme retentit de fa on continue TABLEAU III...

Page 18: ...t moin Pump Cycled La pompe a fonctionn restera allum 3 Pour arr ter l alarme pendant qu on intervient sur le sys t me proc der une r initialisation compl te du syst me comme il est expliqu dans l op...

Page 19: ...ype Pour que la batterie puisse tre install e dans le bo tier n utilis er qu une batterie du type et de dimensions recommand s dimensions maximum 32 4 cm de long 20 3 cm de large et 24 1 cm de haut 12...

Page 20: ...et le tuyau de d eau de la pompe principale et la refoulement de la pompe de puisard de secours et qu il pompe de secours n a pas t fonctionne ad quatement pos ad quatement ou bien il ne fonctionne p...

Page 21: ...D signation Nos de R f des pi ces pi ce 1 Couvercle articul de la batterie 404 117 2 Panneau de commande C014 01 3 Trousse d interrupteur flotteur C015 4 Trousse d triers de brides et d crous C003 5...

Page 22: ...e agua limpia con esta bomba 5 La bomba viene con lubricaci n permanente de f brica No trate de lubricarla 6 Mantenga el cargador de la bater a y la caja de la bater a a una altura m nima de 18 45 72...

Page 23: ...mo refuerzo provisorio para su bomba primaria de sumidero durante un corte de corriente o en presencia de otro problema que impida un funcionamiento normal de su bomba primaria No use este sistema par...

Page 24: ...mba primaria a 1 2 54 cm de distan cia sobre el nivel del agua de encendido on de su bomba de sumidero primaria El fondo de la bomba de refuerzo no debe estar por debajo de esta marca cuando haya term...

Page 25: ...n entre la bomba primaria y la conexi n de la bomba de refuerzo para impedir el retroflujo desde la bomba de refuerzo hacia la bomba de sumidero primaria Consulte la Figura 5 9 Fije los cordones a la...

Page 26: ...as las luces se encienden y permanecen encendi das durante 3 segundos luego se enciende la luz verde Sistema Listo o la amarilla Cargando Corriente Alterna La luz amarilla puede centellear r pidamente...

Page 27: ...as luces est n Consulte el Cuadro II Errores centelleando a una de carga velocidad de un destello por segundo con la alarma activada CUADRO III TABLERO DE CONTROL RESUMEN DE LUCES Y ALARMAS Todas las...

Page 28: ...la luz roja de bomba pas por un ciclo se volver an a encender 3 Para desactivar la alarma cuando est trabajando en el sis tema pase por toda la reposici n del sistema seg n se explicara en el Paso 5...

Page 29: ...una bater a del tipo y del tama o recomendado para que encaje en la caja de la bater a tama o m ximo de 12 75 32 4 cm de largo 8 20 3 cm de ancho y 9 5 24 1 cm de alto incluyendo los bornes y suminis...

Page 30: ...refuerzo tuber a de descarga de la bomba de sumidero de refuerzo no se ha instalado debidamente o no est funcionando correctamente Orificio contra bolsas de Limpie el orificio contra bolsas de aire e...

Page 31: ...pci n Pieza No de la pieza No 1 Caja de bater a a bisagra 404 117 2 Tablero de control C014 01 3 Juego de interruptor de flotador de control C015 4 Juego de abrazadera de soporte C003 5 Empalme para m...

Page 32: ......

Reviews: