Troubleshooting
10
SYMPTOM
PROBABLE CAUSE(S)
CORRECTIVE ACTION
The sump is empty and the
Defective Float Switch.
Disconnect the float switch from the control panel.
float switch is down, but
If the pump stops the float switch needs to be replaced.
the pump won’t shut off.
Defective Control Panel.
If the pump does not stop, replace the control panel.
Pump won’t run.
Float Switch is hung up and
Check that the float switch is free to swing up and down
can’t swing through its
through its entire arc.
entire arc.
Loose electrical connection.
Check all of the connections.
Defective battery or battery
Check for a low or defective battery. The back-up pump will
voltage is too low
not run if battery voltage is less than 8.2 Volt.
(below 8.2 Volts).
Motor hums but pump
Defective battery or battery is
Check for a low or defective battery. Confirm positive and
won’t run.
not charged enough.
negative wires are connected correctly.
Pump runs but pumps very
The check valve, between
Make sure a check valve is installed correctly between
little or no water.
the primary pump discharge
the primary pump discharge and Backup Sump Pump
and the backup pump, is
discharge pipe and is functioning correctly.
installed backwards or not
functioning correctly.
Obstructed anti-airlock hole.
Clean out the anti-airlock hole in the pump body.
The pump discharge pipe is
Check for an obstruction in discharge pipe.
obstructed.
The discharge pipe length or
See Table IV for pumping heights. Increase pipe size.
height is too long for pump’s
capacity.
The battery is not charged
Check for a low or defective battery. An extended power
properly or is defective.
outage may have depleted the battery.
The positive and negative
Reverse the positive (+) and negative (-) wires.
wires are reversed on battery.
Pump cycles too frequently.
Tether length is too short on
The correct tether length is 3-1/2”. Adjust the tether length
the automatic float switch.
accordingly.
The check valve, between the
The primary pump check valve located between the
primary pump discharge and
discharge of primary pump and the Backup Sump Pump
the backup pump, is not
tee is not installed or not working properly. Install or repair
installed properly or not
as required. Confirm that the check valve is installed with
functioning correctly.
the arrow pointing “up”. If the check valve is installed
backward, replace it with a new one.
Excessive water is coming into
Call a plumber.
the sump pit.