background image

Warranty 6

Retain Original Receipt For Warranty Eligibility

Limited Warranty

This Limited Warranty is effective June 1, 2011 and replaces all undated warranties and warranties dated before June 1, 2011.
SIMER warrants to the original consumer purchaser (“Purchaser” or “You”) that its products are free from defects in material and 
workmanship for a period of twelve (12) months from the date of the original consumer purchase. If, within twelve (12) months 
from the original consumer purchase, any such product shall prove to be defective, it shall be repaired or replaced at SIMER’s 
option, subject to the terms and conditions set forth herein. Note that this limited warranty applies to manufacturing defects only 
and not to ordinary wear and tear. All mechanical devices need periodic parts and service to perform well. This limited warranty 
does not cover repair when normal use has exhausted the life of a part or the equipment.
The original purchase receipt and product warranty information label are required to determine warranty eligibility. Eligibility 
is based on purchase date of original product – not the date of replacement under warranty. The warranty is limited to repair or 
replacement of original purchased product only, not replacement product (i.e. one warranty replacement allowed per purchase). 
Purchaser pays all removal, installation, labor, shipping, and incidental charges.
For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact SIMER Customer Service at 
800-468-7867.
Claims made under this warranty shall be made by returning the product (except sewage pumps, see below) to the retail outlet 
where it was purchased or to the factory immediately after the discovery of any alleged defect. SIMER will subsequently take 
corrective action as promptly as reasonably possible. No requests for service will be accepted if received more than 30 days after 
the warranty expires. Warranty is not transferable and does not apply to products used in commercial/rental applications.

Sewage Pumps

DO NOT return a sewage pump (that has been installed) to your retail store. Contact SIMER Customer Service. Sewage pumps 
that have seen service and been removed carry a contamination hazard with them.
If your sewage pump has failed:
•  Wear rubber gloves when handling the pump;
•  For warranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;
•  Dispose of the pump according to local disposal ordinances.

Exceptions to the Twelve (12) Month Limited Warranty

Product

Warranty Period

BW85P, M40P

90 days

2115, 2300, 2310, 2330, 2943, 2955, 2956, 2957, A5500

2 Years

4” Submersible Well Pumps, 2945, 2958, 2975PC, 3075SS, 3963, 3984, 3995

3 Years

Pre-Charged Pressure Tanks, 3985, 3986, 3988, 3989, 5910, 5950, 5955, 5965, 5975

5 Years

General Terms and Conditions; Limitation of Remedies

You must pay all labor and shipping charges necessary to replace product covered by this warranty. This warranty does not 
apply to the following: (1) acts of God; (2) products which, in SIMER’s sole judgement, have been subject to negligence, abuse, 
accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation, maintenance or storage; (4) 
atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or other foreign materials in the system, 
or operation at pressures in excess of recommended maximums.
This warranty sets forth SIMER’s sole obligation and purchaser’s exclusive remedy for defective products.
SIMER SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES WHATSOEVER.
THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED WARRANTIES, 
INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 
PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE DURATION PROVIDED HEREIN.
Some states do not allow the exclusion or limitation of incidental or consequential damages or limitations on how long an 
implied warranty lasts, so the above limitations or exclusions may not apply to You. This warranty gives You specific legal rights 
and You may also have other rights which vary from state to state.

SIMER • 293 Wright Street • Delavan, WI U.S.A. 53115 

Phone: 800-468-7867 • Fax: 800-390-5351 • www.simerpump.com

Summary of Contents for 2300-04

Page 1: ...Installation Fonctionnement Pièces Pour plus de renseignements concernant l utilisation l installation ou l entretien Composer le 800 468 7867 Français Pages 7 11 Instalación Operación Piezas Para mayor información sobre el funcionamiento instalación o mantenimiento de la bomba Llame al 800 468 7867 Español Paginas 12 16 2018 SIM861 02 08 18 5923 0109 2300 04 2305 04 2310 04 2355 04 293 Wright Str...

Page 2: ...ual Branch Circuit Required min 15 Amps Pump Discharge 1 1 4 NPT Adapter 3 4 Garden Hose Risk of fire and explosion Can cause severe injury property damage or death Do not use in explosive atmospheres Pump water only with this pump NOTICE This unit is not designed as a waterfall or fountain pump or for applications involving salt water or brine Use with waterfalls fountains salt water or brine wil...

Page 3: ...uch an operating motor Modern motors can operate at high temperatures 17 Do not handle the pump or the pump motor or change fuses with wet hands or when standing on wet or damp surface or in water Installation 1 Set the pump on a hard surface in at least 2 inches of water 2 Connect the discharge line with the fittings provided 3 The pump should not be installed on clay dirt mud or sand surfaces Al...

Page 4: ...Corrective Action Pump won t start or run Pump is not plugged in Check and see if pump is plugged in to a proper outlet Blown fuse If blown replace with fuse of proper size or reset breaker Low line voltage If voltage is under recommended minimum Check size of wiring from main switch on property If OK contact power company or hydro authority Defective motor Replace pump Pump operates but Restricte...

Page 5: ...10 04 2355 04 1 Power Cord 2300 2305 2355 1 PS117 54 TSU PS117 54 TSU 1 Power Cord 2310 1 PS117 136 TSU 2 Adapter 1 HA5 HA5 3 Cover Motor Assembly 1 4 Inlet Screen 1 PS8 129P 4 Inlet Screen 2305 04 1 PS8 128P 4 Inlet Screen 2355 04 1 PS8 127P If the motor fails replace the entire pump 2300 04 2310 04 2305 04 2355 04 1 2 3 4 5925 0109 ...

Page 6: ...urn a sewage pump that has been installed to your retail store Contact SIMER Customer Service Sewage pumps that have seen service and been removed carry a contamination hazard with them If your sewage pump has failed Wear rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local ...

Page 7: ...aves blessures des dommages matériels voire la mort Ne pas utiliser dans une atmosphère explosive Ne pomper que de l eau avec cette pompe AVIS Cette pompe n est pas conçue pour être utilisée en tant que pompe de fontaine ou de chute d eau ni dans des eaux salées ou de saumure Son utilisation avec une chute d eau une fontaine de l eau salée ou de saumure annulera la garantie Ne pas utiliser où de l...

Page 8: ... immédiatement le cordon électrique s il est endommagé ou usé 16 Ne pas toucher le moteur de la pompe pendant qu il fonctionne Les moteurs peuvent fonctionner par les températures élevées 17 Ne pas manipuler la pompe ni le moteur de la pompe ni remplacer un fusible lorsqu on a les mains humides ou lorsqu on se tient debout sur une surface mouillée humide ou dans l eau INSTALLATION 1 Poser la pompe...

Page 9: ...hée dans une prise de ou ne fonctionne pas courant électrique adéquate Fusible sauté Le remplacer par un fusible de calibre adéquat ou bien réarmer le disjoncteur Tension de ligne basse Si la tension est inférieure à la tension minimum recommandée vérifier le calibre des conducteurs côté sectionneur principal de la propriété Si le calibre des conducteurs est bon s adresser à la compagnie d électri...

Page 10: ...04 2355 04 1 Cordon électrique 2300 2305 2355 1 PS117 54 TSU PS117 54 TSU 1 Cordon électrique 2310 1 PS117 136 TSU 2 Adaptateur 1 HA5 HA5 3 Couvercle du moteur 1 4 Crépine d aspiration 1 PS8 129P 4 Crépine d aspiration 2305 04 1 PS8 128P 4 Crépine d aspiration 2355 04 1 PS8 127P Si le moteur tombe en panne remplacer toute la pompe 2300 04 2310 04 2305 04 2355 04 ...

Page 11: ...ec le service à la clientèle de SIMER Les pompes d eaux d égout qui ont été utilisées puis retirées présentent un risque de contamination En cas de défaillance de la pompe d eaux d égout Porter des gants en caoutchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la...

Page 12: ... 1 4 Adaptador Manguera de jardín de 3 4 Riesgo de incendio o de explosión Puede causar lesiones graves daños materiales o muerte No la use en atmósferas explosivas Bombee solamente agua con esta bomba AVISO Este aparato no está diseñado como bomba de cascada o fuente ni para aplicaciones con agua salada o de mar El uso con cascadas fuentes agua salada o de mar anulará la garantía No usar en donde...

Page 13: ... funcionando Los motores pueden funcionar a temperaturas altas 17 No maneje la bomba el motor de la bomba ni cambie los fusibles con las manos mojadas o cuando esté parado en suelo húmedo o mojado o en el agua Instalación 1 Coloque la bomba sobre una superficie dura dentro de 2 pulgadas de agua como mínimo 2 Conecte la línea de descarga a los accesorios suministrados 3 La bomba no se debe instalar...

Page 14: ...o La bomba no está enchufada Verifique que la bomba esté enchufada en un no marcha tomacorriente adecuado Fusible quemado Si está quemado reemplace por un fusible del tamaño adecuado o reposicione el disyuntor Baja tensión de línea La tensión se encuentra por debajo del mínimo recomendado Verifique el tamaño de los cables desde el conmutador principal en la propiedad Si es el correcto comuníquese ...

Page 15: ...n de la pieza Cantidad 2310 04 2355 04 1 Cordón eléctrico 2300 2305 2355 1 PS117 54 TSU PS117 54 TSU 1 Cordón eléctrico 2310 1 PS117 136 TSU 2 Adaptador 1 HA5 HA5 3 Cubierta unidad del motor 1 4 Malla de admisión 1 PS8 129P 4 Malla de admisión 2305 04 1 PS8 128P 4 Malla de admisión 2355 04 1 PS8 127P Si falla el motor reemplace la bomba completa 2300 04 2310 04 2305 04 2355 04 ...

Page 16: ...evuelva una bomba cloacal que se haya instalado a su tienda minorista Comuníquese con el Departamento de Atención al Cliente de SIMER Las bombas cloacales que hayan estado en servicio y se hayan removido pueden representar un peligro de contaminación Si su bomba cloacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bom...

Reviews: