9
DESCRIPTION
Brava Slim HE ErP
25
30
35
Max operating pressure (PMS)
bar
3
kpa
300
Water content in boiler
l
4,65
4,75
4,95
Lower Heat Output (Hi)
G20 Hi.
9,45 kW/m
3
(15°C, 1013 mbar) -
G31 Hi.
12,87 kW/kg (15°C, 1013 mbar)
1.3.2 Heat pump
DESCRIPTION
SHP M ErP
006
009
012
ELECTRICAL SPECIFICATIONS
Power supply
230V/1/50Hz
230V/1/50Hz
230V/1/50Hz
Maximum absorbed power
kW
2,81
4,61
5,78
Maximum inrush current
A
7,9
13,0
16,4
Maximum absorbed current
A
12,3
20,2
25,4
COOLING
Cooling capacity (1)
kW
3,88
6,10
7,71
Absorbed power (1)
kW
1,34
2,10
2,65
E.E.R. (1)
W/W
2,90
2,91
2,91
Cooling capacity (2)
kW
5,46
8,52
11,8
Absorbed power (2)
kW
1,51
2,36
3,11
E.E.R. (2)
W/W
3,62
3,61
3,80
HEATING
Heat Output (3)
kW
5,40
8,30
11,63
Absorbed power (3)
kW
1,69
2,59
3,64
C.O.P. (3)
W/W
3,20
3,20
3,20
Heat Output (4)
kW
5,65
8,88
12,28
Absorbed power (4)
kW
1,40
2,19
3,02
C.O.P. (4)
W/W
4,05
4,05
4,06
COMPRESSOR
Type
Rotary DC Inverter
Rotary DC Inverter
Twin Rotary DC Inverter
Number
1
1
2
Absorbed power while cooling (1)
kW
1,25
2,16
2,59
Absorbed power while cooling (2)
kW
1,21
2,10
2,73
Absorbed power while heating (3)
kW
1,36
2,26
2,44
Absorbed power while heating (4)
kW
1,18
2,00
2,90
Coolant oil (type, quantity)
mL
ESTER OIL VG74, 480
ESTER OIL VG74, 820
FV50S, 1070
FAN MOTOR
Type
DC Brushless Motor
DC Brushless Motor
DC Brushless Motor
Number
1
1
2
Nominal absorbed power
kW
0,156
0,188
2 x 0,18
Nominal absorbed current
A
0,48
0,57
2 x 0,55
Speed
r/min
900
900
1000
Maximum air flow rate
m
3
/s
1,08
1,63
2,42
COOLANT
Type
R410A
R410A
R410A
Coolant quantity
kg
1,55
2,10
3,65
Project pressure (high / low)
MPa
4,2 / 1,5
4,2 / 1,5
4,2 / 1,5
WATER CIRCUIT
Water flow rate (4)
L/s
0,29
0,45
0,59
Useful flow-head (4)
kPa
43
29
51
Pump nominal power (4)
kW
0,094
0,102
0,125
Pump maximum power
kW
0,124
0,124
0,165
Pump maximum absorbed current
A
0,55
0,55
0,75
Expansion vessel
L
2
2
2
Plumbing connections
inch
1”M
1”M
1”M
Minimum water volume
L
18
25
25
NOISE LEVEL
Sound pressure (5)
dB(A)
44-50
45-53
46-54
DIMENSIONS AND WEIGHTS
Dimensions (WxHxD)
mm
1134x719x373
1229x861x368
1260x1400x448
Max dimensions of package (WxHxD)
mm
1310x850x430
1310x1000x430
1260x1400x448
Operating weight
kg
73
92
135
Net/gross weight
kg
69/77
87/96
140/153
Performance with the following conditions:
(1) Cooling:
external air temperature 35°C; water temperature in/out 12/7°C.
(2) Cooling:
external air temperature 35°C; water temperature in/out 23/18°C.
(3) Heating:
external air temperature 7°C b.s. 6°C b.u.; water temperature in/out 40/45°C.
(4) Heating:
external air temperature 7°C b.s. 6°C b.u.; water temperature in/out 30/35°C.
(5) Sound pressure level measured in free field at 1 m from the unit according to ISO 3744