background image

Enclose:
Explanation
of
the
Error
Codes


In
the
process
of
using,
the
display
of
the
fire,
wind
and
other
patterns
disappeared,
because
the
 

security
device
has
been
caused
by
action.
Display
flashing
fault
code
shows
that
the
failure
of
its
 

occurrence,
the
reason
for
the
exception.
 

Fault
code
has
been
flashing
when
failure.

 

On
such
occasions,
please
turn
off
the
hot
water
value


and
then
open,
or
close
/
open
the
monitor,
and
then
operate
1‐2
times.
If
the
display
 
 still
show
 

the
fault
code,
please
be
sure
to
close
the
water
valve
and
valve,
unplug
the
power
plug,
and
 

contact
the
after‐sales
service.
 


Error
Code


Explanation


01


Inlet
water
temperature
sensor
breaks
down


10


Detect
a
flame
signal
through
pre‐check


11


Ignition
fails


12


Normal
combustion
flames
out
accidentally


13


Thermostat
fault
protection


32


Fan
blocking
protection
 


40


Fan
or
its
drive
circuit
breaks
down


50


Over
high
temperature
protection


outlet
>
80°C

51


Over
high
temperature
protection

inlet
 
 >
65°C

60


Outlet
water
temperature
sensor
fault
protection


80


Timing
protection




Packaging
and
Accessories


Description


Quantity


Gas
water
heater


1
 


Connector
of
gas
inlet
(with
rubber
seal
ring)


1
 


Expansion
screws


1
 


Mounting
screws


2
 


User
manual


1
 


Self‐tapping
screws


2
 


Flue
duct

B

23


type

1
 


Summary of Contents for MINI 12 BF ErP

Page 1: ...TIC INSTANTANEOUS GAS WATER HEATER USER S MANUAL MINI 12 BF ErP Read the technical instruction before installing the appliance Read the user s instruction before lighting the appliance Cod 6328403 09...

Page 2: ...d operating and keep for future reference Contents Special Advice 2 Features Benefits 2 Specifications 4 Parts Name 7 Installation 9 Using Methods 14 Safety Cautions 18 Maintenance 21 Trouble Shooting...

Page 3: ...Control for Automatic Constant Temperature of Outlet Water This function is to monitor the outlet water temperature by a temperature sensor and to transfer the information to the micro computer so th...

Page 4: ...eck protection flame out protection over heat protection accidental power cut protection fan breakdown protection over electric load protection electric leakage protection over wind pressure protectio...

Page 5: ...sure Pw 10bar Min water pressure Pw 0 2bar Electrical power supply 220VAC 50Hz Electric power 33W Degree of electrical protection IPX4 Ignition method Water Control Automatic Pules Ignition Destinatio...

Page 6: ...Parts Name Fig 1 The dimension information is for reference only Please refer to the actual product...

Page 7: ...Fig 2 Unit mm The dimension information is for reference only Please refer to the actual product...

Page 8: ...aller should be called on to install and adjust the appliance where appropriate This product is prohibited to use this gas water heater when flue pipe has not been installed correctly according to ins...

Page 9: ...tant plate and wall gap should be greater than 10mm and the size of heat plate should be larger than water heater shell for 10mm Fig 8 Fig 7 Fig 8 The electric wires and electric equipment are not all...

Page 10: ...e water heater vertically on the upper bolt without inclination and tighten the lower holes with expansion bolts Fig 9 Unit mm 2 Installation of water and gas pipes Fig 10 It can be used when the flue...

Page 11: ...ater piping throughout your structure may be other than copper we recommend that copper piping be used for at least 0 92 m before and after the heater follow local codes Keep water inlet pipe to no le...

Page 12: ...lue duct is the shorter the better The flue duct end should have a 20 downward inclination Fig 11 so as to let the condensing water flows out 4 The distance between the flue duct and the combustible m...

Page 13: ...lbow equivalent 1m straight pipe 3 The distance between the flue duct and the combustible materials should be more than 150mm If the flue duct needs to get through the combustible materials or wall it...

Page 14: ...Using Methods 1 Display Function instruction Display content instruction Touch button instructions...

Page 15: ...water is needed you should press ON button Turn off the water valve and water heater stops working but the fan still blows the combustion chamber for several seconds The machine will show the tempera...

Page 16: ...f saving mode after calculation by microcomputer automatically adjust the amount of gas supply compared other modes more economical by water heater gas consumption not only save gas but also can guara...

Page 17: ...d is automatically cleared For example when the query information display Water production 180m represents a total cumulative amount of water heater 180m When real time gas consumption information sho...

Page 18: ...ns 3 if a valve is installed on the hot water circuit open it If there is a control valve 4 at the hot water outlet please open it Turn the drain valve 5 and take off replace it after the residual wat...

Page 19: ...e gas in different place must not be used Always check the gas pipe and change the pipe every year to avoid gas leakage due to cracking If the flame goes unsteadily stop using the water heater and con...

Page 20: ...rbon every half year to ensure the combustion product discharges smoothly The heater must be installed vertically if inclined it will make the flame touch the heat exchanger and cause the monoxide to...

Page 21: ...o low and the hot water volume is so high so that it exceeds the heater s heating power the outlet water will be not hot enough please reduce the water volume In order to ignite immediately the fan in...

Page 22: ...in gas valve widely There is air in the gas pipe Constantly continue to turn on the water supply control valve High Supply gas pressure inappropr iate Low Contact the technician to check the gas sourc...

Page 23: ...e and valve unplug the power plug and contact the after sales service Error Code Explanation 01 Inlet water temperature sensor breaks down 10 Detect a flame signal through pre check 11 Ignition fails...

Page 24: ...Electrical diagram If change No special advice...

Page 25: ...Conversion instructions...

Page 26: ...ype parameter settings 4 Model selection After gas type is selected press On Off key to both confirm the selection and enter the next selection interface The F that blinks on the display means that yo...

Page 27: ...hether the seal ring on gas control system assembly is fixed well 2 Check the airproof of finished product ensure no gas leakage 3 After finish replacing the conversion kits replace the corresponding...

Page 28: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago VR Telefono 39 0442 631111 Fax 39 0442 631292 www sime it...

Reviews: