background image

Maintenance



 The
appliances
should
be
checked
and
maintained
periodically
by
a
competent
person


Check
the
gas
tube/pipe
regularly
for
any
defect.
Contact
service
center
for
any
doubt.


Always
check
the
gas
pipe
for
cracks.



 Always
check
for
leaking
water.



 Ask
qualified
technicians
to
examine
the
burner,
flue
and
fan
once
a
year.



 Always
check
the
flame
inside
the
water
heater
for
any
abnormal
conditions.



 Keep
the
cover
of
the
water
heater
clean.



 This
product
uses
water
pressure
to
open
the
channels.
When
the
water
pressure
is
lower
 


than
0.2bar,
the
heater
cannot
be
ignited.



 The
drain
valve
is
dripping.
When
the
water
pressure
is
too
high,
the
drain
valve
will
release
 


the
water
so
as
to
reduce
the
pressure
to
protect
the
heater.



 When
the
heater
is
supplying
hot
water
to
several
points
at
the
same
time,
the
hot
water
flow
 


would
be
reduced,
or
no
hot
water
will
issue
at
all.



 When
the
temperature
outside
is
too
low
and
the
exhausted
gas
meets
the
cold
air,
it
will
be
 


condense
as
white
fog.
This
is
normal.



 When
the
water
temperature
is
too
high,
set
to
a
lower
temperature
and
reduce
the
water
 


tap.
If
the
water
temperature
outlet
is
too
high,
please
open
the
tap
to
reduce
the
temperature.



 When
the
water
temperature
is
too
low,
and
the
hot
water
volume
is
so
high
so
that
it
 


exceeds
the
heater’s
heating
power,
the
outlet
water
will
be
not
hot
enough,
please
reduce
the
 

water
volume.



 In
order
to
ignite
immediately,
the
fan
in
the
appliance
will
delay
running
for
a
long
time
and
 


then
stop
automatically.
This
is
normal.



 When
you
use
the
multi‐function
shower,
the
resistance
may
be
too
large,
and
the
water
inlet
 


pressure
will
be
too
low
or
the
water
inlet
volume
will
be
too
little
(below
the
starting
–up
water
 

volume),
there
may
be
flameout
or
can
not
be
ignited,
please
choose
the
suitable
shower
 

function.



 The
residual
water
in
the
heater
may
be
frozen
in
the
winter,
this
is
bad
for
the
heater,
so
you
 


must
drain
the
water
after
use.
(Please
refer
to
the
drain
methods.).



 In
order
not
to
create
scaling,
please
close
the
gas
valve
after
using
the
heater,
let
the
hot
 


water
out
of
the
appliance.
When
the
outlet
of
the
hot
water
is
cold,
close
the
cold
water
valve.


Cleaning

:
The
water
heater
should
be
cleaned
annually,
keep
the
dust
away
from
flue
gas
 


passageway.
See
the
Cleaning
Instructions
below.
(Only
for
service
engineer)

1)
Turn
off
power,
shutoff
gas
supply;

2)
Wait
one
hour
to
cool
down
water
heater;

3)
Remove
the
front
cover,
by
taking
out
Cover
Screw;

4)
Using
compressed
air
or
equivalent
to
clean
the
area
between
the
fins
and
the
heat
exchanger;

5)
Do
not
unscrew
or
move
any
other
parts
of
water
heater;

6)
After
Cleaning,
put
the
front
cover
back.






Summary of Contents for MINI 12 BF ErP

Page 1: ...TIC INSTANTANEOUS GAS WATER HEATER USER S MANUAL MINI 12 BF ErP Read the technical instruction before installing the appliance Read the user s instruction before lighting the appliance Cod 6328403 09...

Page 2: ...d operating and keep for future reference Contents Special Advice 2 Features Benefits 2 Specifications 4 Parts Name 7 Installation 9 Using Methods 14 Safety Cautions 18 Maintenance 21 Trouble Shooting...

Page 3: ...Control for Automatic Constant Temperature of Outlet Water This function is to monitor the outlet water temperature by a temperature sensor and to transfer the information to the micro computer so th...

Page 4: ...eck protection flame out protection over heat protection accidental power cut protection fan breakdown protection over electric load protection electric leakage protection over wind pressure protectio...

Page 5: ...sure Pw 10bar Min water pressure Pw 0 2bar Electrical power supply 220VAC 50Hz Electric power 33W Degree of electrical protection IPX4 Ignition method Water Control Automatic Pules Ignition Destinatio...

Page 6: ...Parts Name Fig 1 The dimension information is for reference only Please refer to the actual product...

Page 7: ...Fig 2 Unit mm The dimension information is for reference only Please refer to the actual product...

Page 8: ...aller should be called on to install and adjust the appliance where appropriate This product is prohibited to use this gas water heater when flue pipe has not been installed correctly according to ins...

Page 9: ...tant plate and wall gap should be greater than 10mm and the size of heat plate should be larger than water heater shell for 10mm Fig 8 Fig 7 Fig 8 The electric wires and electric equipment are not all...

Page 10: ...e water heater vertically on the upper bolt without inclination and tighten the lower holes with expansion bolts Fig 9 Unit mm 2 Installation of water and gas pipes Fig 10 It can be used when the flue...

Page 11: ...ater piping throughout your structure may be other than copper we recommend that copper piping be used for at least 0 92 m before and after the heater follow local codes Keep water inlet pipe to no le...

Page 12: ...lue duct is the shorter the better The flue duct end should have a 20 downward inclination Fig 11 so as to let the condensing water flows out 4 The distance between the flue duct and the combustible m...

Page 13: ...lbow equivalent 1m straight pipe 3 The distance between the flue duct and the combustible materials should be more than 150mm If the flue duct needs to get through the combustible materials or wall it...

Page 14: ...Using Methods 1 Display Function instruction Display content instruction Touch button instructions...

Page 15: ...water is needed you should press ON button Turn off the water valve and water heater stops working but the fan still blows the combustion chamber for several seconds The machine will show the tempera...

Page 16: ...f saving mode after calculation by microcomputer automatically adjust the amount of gas supply compared other modes more economical by water heater gas consumption not only save gas but also can guara...

Page 17: ...d is automatically cleared For example when the query information display Water production 180m represents a total cumulative amount of water heater 180m When real time gas consumption information sho...

Page 18: ...ns 3 if a valve is installed on the hot water circuit open it If there is a control valve 4 at the hot water outlet please open it Turn the drain valve 5 and take off replace it after the residual wat...

Page 19: ...e gas in different place must not be used Always check the gas pipe and change the pipe every year to avoid gas leakage due to cracking If the flame goes unsteadily stop using the water heater and con...

Page 20: ...rbon every half year to ensure the combustion product discharges smoothly The heater must be installed vertically if inclined it will make the flame touch the heat exchanger and cause the monoxide to...

Page 21: ...o low and the hot water volume is so high so that it exceeds the heater s heating power the outlet water will be not hot enough please reduce the water volume In order to ignite immediately the fan in...

Page 22: ...in gas valve widely There is air in the gas pipe Constantly continue to turn on the water supply control valve High Supply gas pressure inappropr iate Low Contact the technician to check the gas sourc...

Page 23: ...e and valve unplug the power plug and contact the after sales service Error Code Explanation 01 Inlet water temperature sensor breaks down 10 Detect a flame signal through pre check 11 Ignition fails...

Page 24: ...Electrical diagram If change No special advice...

Page 25: ...Conversion instructions...

Page 26: ...ype parameter settings 4 Model selection After gas type is selected press On Off key to both confirm the selection and enter the next selection interface The F that blinks on the display means that yo...

Page 27: ...hether the seal ring on gas control system assembly is fixed well 2 Check the airproof of finished product ensure no gas leakage 3 After finish replacing the conversion kits replace the corresponding...

Page 28: ...Fonderie Sime S p A Via Garbo 27 37045 Legnago VR Telefono 39 0442 631111 Fax 39 0442 631292 www sime it...

Reviews: