2.7
LOGICA REMOTE CONTROL
All. the. boiler’s. functions. can. be. mana-
ged. by. a. optional. digital. multifunctional.
device. code. 8092204. for. the. remote. of.
the.boiler.itself.and.for.regulating.room.
climatic. conditions. with. an. operational.
reserve.of.12.hours.
The. heating. circuit. is. controlled. by. the.
room. temperature. sensor. built-in. the.
equipment. or. by. the. atmospheric. con-
ditions,. with. or. without. environmental.
inflow,. if. the. boiler. is. connected. to. an.
external.sensor.
Characteristics:
–
Ergonomic.control.unit.divided.accor-
ding.to.function.(control.levels)).
–
Clear.division.of.basic.functions:
•
. operating. regime,. correction. of.
set. value. and. presence. button. are.
directly.accessible;
•
. Different. real. current. values. are.
accessible. through. the. “info”. but-
ton;
•
. other.functions.can.be.programmed.
after.the.cover.has.been.opened;
•
. special.service.level.with.protected.
access;
–
Each.setting.or.modification.is.displa-
yed.and.confirmed.
–
Tome.setting.(special.line.for.changing.
BST/CET).
–
Heating. programme. with. max.. 3.
heating. periods. per. day,. individually.
selectable.
–
Copy. function. for. easy. transfer. of.
heating. programme. to. the. next. or.
previous.day.
–
Holiday. programme:. the. programme.
is. interrupted. for. the. holiday. period.
and. automatically. restarted. on. retur-
ning.home.
–
Option. to. return. the. heating. program.
to.default.values.
–
Programming.lock.(child.safety).
Functions:
–
Delivery. temperature. control. guided.
by. the. atmospheric. conditions,. taking.
into.account.the.dynamics.of.the.buil-
ding.
–
Delivery.temperature.control.guided.by.
atmospheric.conditions.with.influence.
of.ambient.temperature.
–
Ambient.temperature.control.only.
–
Adjustable. influence. of. ambient. tem-
perature.shift..
–
Switch-on. and. switch-off. optimisa-
tion.
–
Rapid.lowering.
–
ECO. functions. (daily. heating. limiter,.
automatic. summer/winter. switch-
over).
–
Controllable. maximum. delivery. tem-
perature. limit. (specifically. for. floor.
plants).
–
Limitation.of.increase.in.pre-set.deli-
very.temperature.
–
Anti-freeze.protection.for.buildings.
–. Hourly. programming. of. the. tank. unit.
temperature. on. two. levels:. comfort.
and.reduced.
–
Domestic.hot.water.control.with.nomi-
nal.value.requirement.and.enable.
–
Connection. to. room. sensor. or.
switching.of.operating.regime.through.
the. telephone. system. with. external.
contact.or.through.a.window.contact.
–. Anti-bacterial.
2.7.1 Installation
The. unit. must. be. installed. in. the. main.
living. room.. For. installation,. follow. the.
assembly. instructions. inserted. in. the.
package..
At.this.point,.with.the.selector.knob.on.
(
),.the.installer.can.adjust.the.basic.
parameters. settings. according. to. the.
individual.needs..
If there is a thermostatic radiator valve
fitted, this must be set to maximum.
2.7.2 Installation settings
The.settings.for.the.basic.operating.para-
meters.for.individual.needs.are.reported.
in. the. instruction. leaflet. supplied. with.
the. “Logica. Remote. Control”. and. in. the.
section. reserved. for. the. user. in. this.
manual.
For. further. adjustments. which. can. be.
carried. out. by. the. installer,. the. “Logica.
Remote.Control”.offers.a.level.of.service.
and. parameterising. which. can. only. be.
accessed.through.a.special.combination.
of.buttons.
To.activate.this.level.of.service.or.para-
meterising. press. buttons
and.
least. 5. seconds.. This. will. activate. the.
parameterising.level..Then.use.the.same.
arrow. buttons. to. select. the. individual.
input. lines. and. adjust. the. values. with
or.
.
98
Antifreeze protection
“Pre-set ambient
temperature value”
Summer/Winter switch-over
temperature
Type of control:
0 = with ambient influence
1 = without ambient influence
Influence of ambient temperature
Heating.takes.place.up.to.this.pre-set.value.if.the.plant.is.activated.in.
standby.(e.g..holidays)..
In. this. way,. the. building. antifreeze. function. is. active,. preventing. an.
excessive.lowering.of.the.ambient.
This.parameter.regulates.the.temperature.of.the.automatic.summer/
winter.switch-over.
This.parameter.de-activates.the.ambient.influence.and.as.a.result.all.
the.optimisations.and.adaptations..
If. a. valid. external. temperature. is. not. transmitted. ,. the. controller.
switches.to.the..pure.ambient.control.guide.variable.
If.the.ambient.controller.is.used.only.as.a.remote.control.(placed.in.the.
reference.room.and.without.an.external.sensor.connected),.the.value.
must.be.set.at.0.(zero)..
If.the.change.in.ambient.temperature.from.the.pre-set.value.remains.
high. during. the. entire. day,. the. influence. must. be. increased.. If. the.
ambient.temperature.is.around.the.pre-set.value.(control.oscillation),.
the.influence.must.be.reduced..
Note: If the ambient temperature influence constant is set at 0, the
adaptation of the heating curve is deactivated. In this case, parameter
57 will have no effect at all.