1.6
COMBUSTION CHAMBER
The combustion chamber is of the straight
flow type and complies with standard EN
303-3 appendix E.
The dimensions are shown in fig. 3.
1.7
COMPATIBLE BURNERS
In general, the oil burner that is compatible
with the boiler should use spray
of the semi solid type.
Sections 1.7.1 shows the matching table of
the burners NOx: Class 3 together with the
boilers have been tested with.
L
270
280
Fig. 3
L
Volumen
mm
dm
3
Estelle HE 4
405
24,0
Estelle HE 5
505
30,5
1.7.1
“FBR” burners - NOx: Class 3 (Burner with low polluting emissions)
Model
Nozzle
Atomising
Pump
Type
ø
angle
pressure
bar
Estelle HE 4
G 0S - LX TXC
DANFOSS
0,60
45°H
12,0
Estelle HE 5
G 1S - LX TC
DANFOSS
0,75
45°H
13,5
36
1.5
FUNCTIONAL DIAGRAM
KEY
1
Boiler
2
Stainless steel condenser
3
Condensate drain tap
M
C.H. flow
R
C.H. return
Fig. 2/a