33
Type
No.
Description
Range
U/M
Step
Default
PAR
24
External relay 2 function
0 = not used; 1 = remote alarm NO; 2 = remote alarm NC; 3 = zone
valve; 4 = automatic filling; 5 = external request; 6 = recirculation
pump; 7 = zone valve with OT; 8 = relaunch pump; 9 = boiler with heat
pump
0 .. 9
-
-
0
PAR
25
Auxiliary TA function
0 = according to TA
1 = TA Antifreeze
2= domestic hot water disabled
0 .. 2
-
1
0
PAR
26
Zone Valve / Pump Relaunch Delay
0 .. 99
Min
1
1
PAR
29
Anti-legionella Function (Only hot water tank)
-- = Disabled
50 .. 80
-
1
--
PAR
35
Digital / analogue Pressure switch
0 = water pressure switch
1 = water pressure transducer
2 = water pressure transducer (only pressure displayed)
0 .. 2
-
1
1
PAR
40
Modulating Pump Speed
-- = No modulation
AU = Automatic 30
.. 100
%
10
AU
PAR
41
∆T Modulating pump delivery/Return
10 .. 40
°C
1
20
PAR
42
Select heat pump or boiler convenience (only if PAR 02 = 6)
-20 .. 30
°C
-
5
PAR
43
Heat pump boiler aid activation delay (only if PAR 02 = 6)
1 .. 60
Min
-
3
PAR
47
System pump forcing (only in winter mode)
0 = Disabled
1 = Enabled
0 .. 1
-
1
0
RESET
PAR
48
INST Parameter set to default
0 .. 1
-
-
0
In the event of a fault/malfunction the message
“ALL”
will appear
on the display with the alarm number eg.
“ALL 05”
(Domestic
Hot Water Sensor Fault).
Before repairing the fault:
– disconnect the appliance from the mains power by setting the
main switch to "OFF"
OFF
Fig. 41
– as a precautionary measure, close the gas isolation valve.
Repair the fault and start-up the boiler again.
NOTE:
after having repaired the fault, when the alarm number
appears on the display together with the message
d
(see figure), press the button
y
for approximately 3 seconds
to start the appliance up again.
9.5
Fault / malfunction codes
Type
No.
Description
AL
02
Low water pressure in system
AL
05
Delivery sensor fault
AL
06
No flame detection
AL
07
Safety thermostat intervention
AL
08
Fault in the flame detection circuit
AL
09
No water circulating in the system
AL
10
Auxiliary sensor fault
AL
11
Gas valve modulator disconnected
AL
12
Incorrect configuration of the open /sealed chamber
AL
13
Smoke probe intervention
AL
14
Smoke probe fault
AL
15
Fan check cable disconnected
AL
18
Condensate level fault
AL
28
Maximum number of consecutive releases
ALL
30
Return sensor (SR) fault
AL
37
Fault due to low network voltage
AL
40
Incorrect network frequency detected
AL
41
Flame loss more than 6 consecutive times
AL
42
Button fault
AL
43
Open Therm communication fault
ALL
44
No flame valve opening time sum anomaly
AL
62
Self-calibrating procedure is required
AL
72
Incorrect positioning of the delivery sensor
ALL
77
EV2 SGV current max/min absolute limits error
ALL
78
EV2 SGV current upper limit error
ALL
79
EV2 SGV current lower limit error
Summary of Contents for Brava Slim HE 20 R i
Page 4: ...4 ...
Page 42: ...42 12 EXPLODED VIEWS Brava Slim HE 20 R i Brava Slim HE 40 R i ...
Page 43: ...43 Brava Slim HE 20 R e Brava Slim HE 40 R e ...
Page 44: ...44 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 45: ...45 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 46: ...46 Brava Slim HE 20 R i Brava Slim HE 20 R e Brava Slim HE 40 R i Brava Slim HE 40 R e ...
Page 55: ...55 ...