![Sime BRAVA One HE 25 Installation And Maintenance Manual Download Page 58](http://html.mh-extra.com/html/sime/brava-one-he-25/brava-one-he-25_installation-and-maintenance-manual_1274924058.webp)
58
1.5
Technical features
DESCRIPTION
Brava One HE
25
30
CERTIFICATIONS
Country of intended installation
IT – ES – PT – GR – SI
Fuel
G20 /G31
PIN number
1312CO5936
Category
II2H3P
Type
B23P - B53P - C13 - C33 - C43 - C53 - C63 - C83
Class NO
x
5 (< 70 mg/kWh)
HEATING PERFORMANCE
HEAT INPUT
Nominal
kW
20
24
Minimum
kW
4,0
4,8
HEAT OUTPUT
Nominal (80-60°C)
kW
19,7
23,6
Nominal (50-30°C)
kW
21,4
25,7
Minimum G20 (80-60°C)
kW
3,9
4,7
Minimum G20 (50-30°C)
kW
4,3
5,1
Minimum G31 (80-60°C)
kW
3,9
4,7
Minimum G31 (50-30°C)
kW
4,3
5,1
EFFICIENCY
Max useful efficiency (80-60°C)
%
98,5
98,3
Min useful efficiency (80-60°C)
%
97,5
97,9
Max useful efficiency (50-30°C)
%
107,0
107,1
Min useful efficiency (50-30°C)
%
106,0
106,4
Useful efficiency at 30% of load (40-30°C)
%
107,0
107,0
Thermal efficiency (EEC 92/42)
Losses after shutdown at 50°C
W
84
88
DOMESTIC HOT WATER PERFORMANCE
Nominal heat input
kW
24
28
Minimum heat input
kW
4
4,8
D.H.W. flow rate Δt 30°C
l/min
11,2
12,9
Continuous D.H.W. flow rate (Δt 25°C / Δt 35°C)
l/min
13,6 / 9,7
16,1 / 11,5
Minimum D.H.W. flow rate
l/min
2,2
2,2
Max / Min Pressure
bar
7 / 0,5
7 / 0,5
kpa
700 / 50
700 / 50
ELECTRICAL SPECIFICATIONS
Power supply voltage
V
230
Frequency
Hz
50
Absorbed electrical power
W
105
114
Electrical protection degree
IP
X5D
COMBUSTION DATA
Smoke temperature at Max/Min flow (80-60°C)
°C
82 / 66
89 / 71
Smoke temperature at Max/Min flow (50-30°C)
°C
59 / 45
71 / 51
Maximum smoke flow Min/Max
g/s
11,2 / 1,9
13,1 / 2,2
CO
2
at Max/Min flow rate (G20)
%
9,0 / 9,0
9,0 / 9,0
CO
2
at Max/Min flow rate (G31)
%
10,0 /10,0
10,0 /10,0
NOZZLES - GAS
Number of nozzles
No.
1
1
Nozzle diameter (G20-G31)
mm
5,3
5,3
Gas consumption at Max/Min flow rate (G20)
m
3
/h
2,53 / 0,42
2,96 / 0,50
Gas consumption at Max/Min flow rate (G31)
Kg/h
1,86 / 0,31
2,17 / 0,37
Gas supply pressure (G20/G31)
mbar
20 / 37
kpa
2 / 3,7
TEMPERATURE - PRESSURE
Max operating temperature
°C
85
85
Heating adjustment range
°C
20÷80
20÷80
Domestic hot water adjustment range
°C
10÷60
10÷60
Max operating pressure
bar
3
kpa
300
Water content in boiler
l
4,65
4,75
Lower Heat Output (Hi)
G20 Hi.
9.45 kW/m
3
(15°C, 1013 mbar) - G31 Hi. 12.87 kW/kg (15°C, 1013 mbar)
EN
Summary of Contents for BRAVA One HE 25
Page 27: ...27 ES ...
Page 53: ...53 PT ...
Page 79: ...79 EN ...
Page 105: ...105 RU ...
Page 106: ...106 ...
Page 107: ...107 ...