When
the
vertical
extension
code
8086950 is used, the terminal part of the
pipe must always come out horizontally.
2.7.3
Coaxial duct outlet on the roof
The accessories to be used for this type of
installation and some of the connecting
systems that may be adopted are illustra-
ted in fig. 7.
It is possible to insert the extensions and
reach a maximum rectilinear distance of
5 meter.
Should it be necessary to make two chan-
ges of direction in the pipe development,
the maximum length of the pipe must not
exceed 4 meter.
2.8
SEPARATE PIPES ø 80
The kit for duct separation code 8089912
(fig. 8) enables to separate the exhaust
Fig. 7
KEY
1
Vertical extension L. 140 with take-off points code 8086950
2a Extension L. 1000 code 8096150
2b Extension L. 500 code 8096151
3
Tile with articulation joint code 8091300
4
Roof outlet terminal L. 1285 code 8091205
5
Supplementary 90° elbow code 8095850
6
Supplementary 45° elbow code 8095950
max
5
m
NOTE
Before connecting accessories, it is always advisable to lubricate
the internal part of the gaskets with silicon products. Avoid using
oils and greases.
Use of the ø 87.5 diaphragm
supplied as standard
With
Without
diaphragm
diaphragm
L min = 0 m
L min = 3 m
L max = 3 m
L max = 5 m
11
5
ø 80
ø 80
11
0
16
5
255
100
245
Fig. 8
Fig. 8/a
N° segments
Total load loss mm H
2
O
to remove
“30 PC”
model
n° 1 e 2
0 ÷ 2,0
da n° 1 a 3
2,0 ÷ 3,0
da n° 1 a 4
3,0 ÷ 4,0
da n° 1 a 6
4,0 ÷ 5,0
da n° 1 a 8
5,0 ÷ 6,0
without diaphragm
6,0 ÷ 7,0
1
2
3
4
KEY
1
ø125/95 sponge seal
2
Fixing screw
3
Flue outlet flange with connection
4
Inlet air diaphragm