40
1.1
INTRODUCTION
The cast iron boilers “1R/2R OF - 2R
OF S” for gas-oil or gas has been de-
signed in compliance with the Europe-
an Directives 2009/142/CE, 2014/30/
UE, 2014/35/UE, 92/42/CEE. The cast
iron boilers “2R GT OF” for gas-oil has
been designed in compliance with the
European Directive 92/42/CEE.
The components for “1R/2R OF” in-
stallation are supplied in three se-
parate packages: boiler body with
smoke chamber dismantled and in-
serted in the combustion chamber,
casing with enclosed documents and
control panel.
Instead, the boilers “2R OF S” are
supplied with the dismantled boiler
body.
The boilers “2R GT OF” are supplied
in four separate packages, as they
come with a gas oil burner and rela-
ting instructions.
1 BOILER DESCRIPTION
6
7
8
9
10
Output
kW
64.8
74.0
84.0
93.3
102.1
kcal/h
55,700
63,600
72,200
80,200
87,800
Input
kW
73.4
83.1
93.8
103.4
113.5
kcal/h
63,100
71,500
80,700
88,900
97,600
P (depth)
mm
595
670
750
825
900
Sections
n°
6
7
8
9
10
Maximum water head
bar
4
4
4
4
4
Water content
l
37.5
42.0
46.5
51.0
55.5
Loss of head smoke
mbar
0.20
0.16*
0.22*
0.30*
0.35*
Comb. chamber pressure
mbar
– 0.01
0.06
0.08
0.08
0.10
Suggested chimney depression
mbar
0.21
0.22
0.30
0.38
0.32
Smokes temperature
°C
225
217
209
201
192
Smokes flow
m
3
n/h
68.0
77.7
88.0
97.6
107.5
Adjustment range
Heating
°C
30÷85
30÷85
30÷85
30÷85
30÷85
Smokes volume
dm
3
42
46
50
55
60
Weight
kg
261
293
325
357
389
1.3
TECHNICAL FEATURES
1.3.1 “1R OF” boiler
560 (1R) - 700 (2R)
1030 (1R) - 1235 (2R)
P
125 (1R)
135 (2R)
ø 150 (1R) ø 200 (2R)
270 (1R) 330 (2R)
70 (1R) 85 (2R)
695 (1R) - 875 (2R)
865 (1R) - 1075 (2R)
M
R
S
1.2
DIMENSIONAL DETAILS
Fig. 1
1R OF
2R OF/OF S/GT OF
M C.H. flow
1
1/2
”
2”
R C.H. return
1
1/2
”
2”
S Boiler/filling drain 3/4”
3/4”
* Without baffles