9 Faults
9.1 Faults ThunderION
Table 4, faults when connected to a 24 V DC power supply
Signaling Problem
Cause
Remedy
Green
No/poor ionisation
However high voltage
on emitters
(can be checked with
a high voltage meter/
Tension)
Anti-static bar is fouled.
Clean anti-static bar.
Continuous
Emitters are damaged.
Replace emitters.
HVOK active
(external)
Emitters are covered.
Remove the cover.
Position of neutralizing not OK Change position
No LED
No high voltage on
emitters.
Cable, connectors or power
supply not connected
Restore supply voltage
HVOK not
active
(external)
Bar faulty.
Return anti-static bar
Green flashing
HVOK not
active
(external)
No high voltage on
emitters.
“Remote operation” input is
not controlled
Set Remote to On
(5.6.2)
Red
Continuous
(lower) High voltage
on emitters
Bar placed too close to
conductive parts
Move anti-static bar.
HVOK not
active
(external)
Bar is extremely fouled.
Clean anti-static bar.
Bar faulty.
Return anti-static bar.
Red
flashing
Internal hardware
error
Supply voltage too low
Check power supply
and length of the cable
Internal Temp too high
Tamb> 55C or anti-
static bar faulty
HV OK overload
Reduce load