P-SH-N-Ex 97.52.03.14.20
01/08
14
4. Technical specifications
Mains voltage
230 V AC
110 V AC
380-460 V AC
Line-side fuse
200 mAT
400 mAT
100 mAT
Operating voltage
approx. 7 kV
Max. current
25
μ
A (from emitter point to earth)
Operating distance
50 - 200 mm
Operating temperature
0 - 40°C
Maximum surface temperature
of the power unit
135 °C
5. Installation
5.1. Checks
−
Check that the anti-static bar is undamaged and that you have received the correct version.
−
Check that the data on the packing slip corresponds with the data shown on the product
received.
If you have any problems and/or in the case of ambiguity:
Please contact SIMCO or your regional agent.
5.2. Installation
5.2.1. Summary
Warning:
−
Do not cover the anti-static bar at the rear or at the front, a free passage of air is
essential to ensure proper functioning.
Fit the anti-static bar right at a location where static electricity causes danger
In places where the material is neutralized, it may not be surrounded by grounded objects.
Distance between the bar and grounded objects must be greater than the distance from the bar
to the material to be neutralized.
Fit the anti-static bar at a distance of 50 to 200 mm from the material,
the correct distance should be established by experiment.
5.2.2. Mounting
Warning:
−
Make sure the supply voltage is correct (see rating plate).
−
Fit the connecting line such that it cannot suffer mechanical damage.
−
Earthing is needed to ensure a proper and safe operation.
−
Fit the anti-static bar with the emitter points towards the material to be discharged.
−
Mount the bar in such manner that the emitter points are not subject to mechanical damage.
−
Use the facilities specially fitted for mounting purposes.
−
Fit the connecting line to the (mains) voltage connection for the anti-static bar using
appropriate connectors and fix the cable securely to prevent mechanical damage.