5 Installation
Warning:
-
Before using the Performax IQ Easy Ex Speed in an explosive hazardous area, check
whether it is permitted to be used in the zone classification of the hazardous area.
-
Mount the Performax IQ Easy Ex Speed in a manner that provides complete protection
against impact.
-
Only the Performax IQ Easy Ex Speed with fixed wiring can be installed in the
hazardous area. The Ex Status Module and any other connected devices must be
mounted outside the Ex zone.
-
Electrical installation and repairs must be done only by a skilled electrical engineer
and in accordance with all national and local regulations.
-
When working on the equipment, the equipment must be disconnected from the
power supply.
-
The equipment must be properly grounded. Earthing is necessary to ensure safe
operation and to prevent any electrical shock when touched.
-
Connect the ground terminal on the anti-static bar to a grounded part of the machine
with a wire of a minimum size of 4mm
2
.
-
Use the Performax IQ Easy Ex Speed always in combination with the Ex Status
Module and IQ Easy Manager and / or Extension IQ Easy.
The anti-static bar is powered and controlled via the IQ Easy Platform.
See the list of spare parts and accessories for the available IQ Easy Managers and Extension
IQ Easy.
5.1 Simplified system overview
A Status Module is needed for each anti-static bar. The anti-static bar is connected to the Status
Module through the wires at a connector block in the Status Module. For instructions, see 5.8.2.
The Status Module is connected with the Manager IQ Easy.
5.2 Product Check
- Make sure the equipment is undamaged and that the correct version is received.
- Make sure the packing slip corresponds with the data of the received product.
Should you have any problems and / or questions, please contact Simco-Ion or the local agent
in your area.
Image 5.1.1: System overview